2. Fit the inlet module onto the bottom cone. Secure it with the locking ring.
3. Fit the module ring onto the inlet module. Secure it with the locking ring.
4. Fit the filter plate onto the module ring. Secure it with the locking ring.
5. Fit 4 filters. Affix them with 4 locking ring(s).
6. Connect the filter grounding.
7. Mount the filter cleaning unit (the tank) on the filter plate. Then secure it with the star knob.
8. Fit the outlet module onto the filter plate. Secure it with the locking ring. Pass the cable through the bulkhead entry. Connect
the compressed air hose.
9. Fit the cover onto the outlet module. Secure it with the locking ring.
10. Fit the drawbars.
11. Connect equalization cables on the outside of the cyclone.
After fitting the filter cyclone, the following must be done:
1. Connect inlet and outlet.
2. Connect the filter cleaning unit to compressed air and control voltage from the control cabinet. For detailed values, see
Technical Data
.
3. Ensure potential equalization.
Trial run
Make sure that the vacuum generator is correctly installed and that the inlet and outlet are connected to the piping system. The
piping system between the filter cyclone and the vacuum generator must be free of particles. Check the grounding of the piping
system between the units in the system.
Verify that the output device is securely fastened so that no air is sucked in that way and that the barrel is properly grounded.
Verify that the automatic filter cleaning works.
Maintenance
It is important that the cyclone's filters are replaced as they can no longer be cleaned effectively. The intervals between the
changes depend entirely on the material being sucked, the flow of the system and the operating time.
Filter replacement
Filters must be changed at least once a year. Depending on operating conditions and shifts, they may need to be replaced more
often. Do not expose unprotected dust to hazardous dust.
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable equipment.
Only Dustcontrol original filters may be used. If other filters are used, the risk of explosion may increase. Guarantees also expire.
1. Turn off and lock the vacuum producer's circuit breaker.
2. Put on safety gear.
3. Empty the compressed air-tank.
4. Remove the cover of the dust separator.
5. Remove the filters and put them in a plastic bag. Seal the bag.
6. Vacuum filter plate and casing.
7. Put the new filters in place, and put the cover back on the dust separator.
8. Ground the filters.
Explosion panel
Information regarding maintenance of the explosion panel can be found in a separate document from the supplier.
Technical Data
According to design, the maximum ATEX zones for the filter units are as follows:
•
The dirty side
of the filter is sufficient up to Zone 21
•
The clean side
of the filter is sufficient up to Zone 22
•
The area around the unit
is sufficient up to Zone 22. Observe the safety instructions from the supplier regarding the explosion
panel.
S34000 EX, Art no. 99060-A
15
ENGLISH