DC AirCube X2 - 10
Part No 9462
Service
While performing cleaning or maintenance on the
machine, the unit should be switched off and discon-
nected from the power supply.
At normal use the pre-fi lter should be exchanged every
700 hours and the HEPA fi lter every 2100 hours. Check
the condition of the HEPA fi lter by exchanging the
pre-fi lter (turn the ”soft” surface out and the ”hard”
turn the ”soft” surface out and the ”hard”
surface towards the HEPA-fi lter)
surface towards the HEPA-fi lter) and than checking
the suction effi
ciency of the unit.
With heavy dust loads the life of the fi lters are shorter.
Use only original spare part fi lter 4080. Use suitable
breathing protection and do the operation in a closed
room. Th
e used fi lter should be sealed in a plastic bag
and disposed of according to approved methods.
Check regularly that the electrical cable is not damaged
in any way. With replacement of the cable and contact,
use only water proof replacements.
Th
e DC AirCube X2 should be performance tested
and checked at least once per year or more frequently
if subject to intensive use.
Because this machine is used with dangerous sub-
stances maintenance is vital, worn parts should be
replaced.
Never compromise the function of the DC AirCube
X2, use only original spare parts.
Th
e fan is maintenance free
.
Th
e warranty period for this machine is two years and
covers manufacturers faults. Th
e warranty is valid under
the condition that the machine is used under normal
conditions on the task for which it was designed and
is maintained properly. Normal wear is not covered by
this warranty.
Warranty
Service performed by other than Dustcontrol or its
authorized agent voids automatically the warranty. No
other warranty express or implied is applicable
.
Description Part
no
Pre-fi lter
4080
HEPA fi lter
42136
Hose φ 125 mm
2420
Silencer
3228
Other accessories — see Dustcontrol catalo-
gue.
Accessories