9
ENGLISH
Solution Level Indicator
The solution Tank Drain Hose also serves as a water level
indicator for the solution tank. The amount of water remaining
in the solution tank can be seen through the clear drain hose.
Brush Removal
•
Use a 4mm or 5/32 Hex Tool to remove the flat-head
screw on the underside of the right side of the brush
housing.
•
Pry open the brush housing door.
•
Pull brush straight out to the side.
To re-install:
•
Insert the end of the brush with drive lugs first,
to match the drive hub on the left side.
•
Twist the brush until the drive hub locks
in to the brush.
•
Close the brush housing door. The bearing in the door
will insert itself into the end of the brush.
•
While holding the housing door closed, reinstall
flat-head screw from the underside of the housing.
Brush Pressure Gauge
The brush pressure gauge informs the operator if the brush
pressure setting is in optimum range. The machine operates
best in the green area. If the machine reaches the yellow
or red range the brush pressure can be lowered by raising
the brush by turning the brush pressure adjustment knob
counter-clockwise.