OPERATION

THE HYPASTART IS DELIVERED CHARGED AND READY TO 

USE, HOWEVER, EXTENDED PERIODS OF TIME MAY ELAPSE IN 

SHIPMENT OR STORAGE DEPLETING THE STORED CHARGE. 

Make sure the starting leads are not connected to a 
battery, simply turn the switch to the energize position. 

The SUPERCAPACITOR STATUS LCD will display internal 
voltage and capacity level. If there is enough stored energy 
the GREEN READY LIGHT will come on indicating the unit is 
ready to use, if the green ready light does not illuminate and 
the capacity and voltage is lower than 13.5V then energizing/
charging the HYPASTART will be required before use.

Please note that the ready light will turn on when the 
capacity level reaches approximately 50% or 13.5V. There 
is enough energy to start most vehicles but if you require 
extended crank times or the engine is of very large 
displacement please charge the HYPASTART to 100% 
before attempting to start.

If the Vehicle voltage is above 8V (for a 12V vehicle) 
or 16V (for a 24V vehicle) the vehicle battery can be used
to energize the Hypastart.

Switch the Hypastart to the off position.
Connect the + Positive red lead clamp to
the battery terminal
Connect the – Negative clamp as far away from 
the battery as possible and to a non-moving 
metal part of the engine or chassis block

Turn the switch to the energize position, if a red 
light comes on, this indicates the charge has 
begun

HOW TO CHECK THE STATUS AND

CAPACITY OF THE HYPASTART 

ENERGIZING/STARTING

AN ENGINE 

STEP 

1.

STEP 

2.

STEP 

3.

STEP 

4.

When the green light illuminates, turn the switch 
to the start position and start your engine

STEP 

5.

Let the Hypastart run for 10 seconds once the 
engine is started. This will recharge your unit. 

STEP 

6.