5.2 Replace UV-C lamps
1. Switch off the device and disconnect the
power cord (1).
2. Remove the maintenance cover (2) on the
back side of the core-unit.
The maintenance cover is attached
magnetically.
3. Unscrew the Phillips head screws (3) to
remove the defect module’s lamp
cover (4).
Illustration shows upper module.
4. Remove all lamp retaining plates (5).
Every UV-C lamp is secured by four
retaining plates (5).