8.4
Replacing the fine filter (5 µm)
in the condensate separator
❯
Use an SW 4 Allen key to loosen the cheese
head screws attaching the holding bracket
(pressure reducer with condensate separator)
to the frame of the unit.
❯
Disconnect two hoses as shown from the con-
densate separator. Press back the release ring
on both sides with your fingers or using a
release tool and keep it pressed in this posi-
tion. Pull the hose straight out of the push fit
connection.
20
21
22
21
22
5
19
21
22
5
Pressure reducer with condensate separa-
tor
19
Holding bracket
20
Hexagon socket screws with washer
21
Release ring
22
Hose
❯
Take out the condensate separator to the top,
allowing the condensate hose to remain on the
condensate separator.
❯
Loosen the cover of the condensate separator
by twisting it clockwise.
❯
Replace the filter element of the fine filter and
close it off with a black sealing cap.
❯
Screw on the cover of the condensate separa-
tor. Push in the hoses as far as they will go into
the relevant push fit connection and lightly tug
on them to check they are securely seated.
Avoid subjecting the hose connections to ten-
sile forces or torsion forces.
23
24
25
23
Cover of the condensate separator
24
Fine filter filter element
25
Sealing cap
❯
Screw the holding bracket for the pressure
reducer with condensate separator to the
frame of the unit and close the cover of the
unit.
8.5
Checking the fan
Perform a monthly visual inspection of the fan to
check that it moves freely. If a fan is locked the
unit must be taken out of operation. The fans run
constantly when the compressor is operational.
Usage
22
0715100100L02 2111V005
EN