6046100064L02 1702V002SE
19
Installation
Installation example with a water treatment
system
1
2
3
4
5
6
7
8
9
10
11
12
13
Installation example e.g. Hygopure 90
(schematic diagramme)
1 Cover for waste water container and fresh
water container
2 Connection for "automatic water drain"
3 Connection for "automatic fresh water sup-
ply connection"
4 Removal of demineralized water
5 Wall drain (NW 40 – provided on-site)
6 Double chamber siphon with Y-piece
7 Concentrate drain from water treatment
system
8 Automatic fresh water supply connection
9 Automatic water drain
10 Water treatment system
11 Aqua-Stop
12 Water tap (provided on-site)
13 Electrical connections
The device is supplied with demineralised water
directly via a hose from the water treatment
system�
Electrical connections
Electrical safety when making connections
i
The device must only be connected to a cor-
rectly installed and earthed power outlet�
i
Do not use movable multi-way power outlets�
i
Make sure that none of the electrical cables
leading to the unit are under any mechanical
tension�
i
Before start-up, check the mains voltage
against the voltage indicated on the type plate
(see also "4 Technical data")�
7.6 Checking the sterile air filter
i
Open the cover�
i
Check to make sure that the sterile air filter is
pushed in as far as it will go�
i
Close the cover�
7.7 Connecting the unit
Installation examples
Example of a standard installation
1
2
3
4
Installation example – standard delivery state
1 Cover for waste water container and fresh
water container
2 Connection for "automatic water drain"
3 Connection for "automatic fresh water
supply connection"
4 Electrical connections
The unit is supplied with fresh water directly via
a hose from the internal fresh water container�
No additional water connection is required�
The waste water either collects in the internal
waste water container, or (if a hose for "auto-
matic water discharge" is connected) it flows
away directly� A message is displayed when the
waste water container is full� The waste water
then needs to be manually drained�