5
Operation
1
2
6
4
8
5
3
7
9
10
11
13
12
1
Air intake filter
2
Compressor unit
3
Pressure tank
4
Safety valve
5
Compressed air connection (3/4")
6
Pressure gauge/display
7
Automatic/manual condensate drain valve,
membrane drying unit
8
Sintered filter for membrane drying unit
9
Condensate drain valve
10 Fuse box
11 Fine filter or sterile filter, membrane drying
unit
12 Controller
13 Intake connector
The compressor unit draws in atmospheric air
and compresses it without oil. It then transports
the oil-free compressed air to the membrane dry-
ing unit. The cooler and the membrane dryer
extract moisture from the compressed air. The
oil-free, hygienic and dry air is stored in the pres-
sure tank ready for use in connected devices.
All of the measurement data for the unit comes
together in the control (e.g. pressure in the pres-
sure tank, temperature of the motor windings),
where it is then evaluated. Likewise, various set-
tings (e.g. switch-on/cut-off pressure) can be
adjusted, or the unit can be connected via the
network to monitoring software.
5.1
Operating panel
1 2 3 4
5
6
1
Fault button with orange LED
2
Filter change button with orange LED
3
Service key with blue LED
4
Standby button with blue LED
5
Pressure range display/adjustment
6
Pressure dew point display
Different messages and the status of the unit are
displayed on the operating panel. In addition, dif-
ferent functions can be started via the buttons.
5.2
Start-up behaviour
On compressors with an electronic controller, the
compressor units are switched on with a time
delay. The time delay depends on the operating
mode selected on the controller.
Operating mode:
– Eco: 180 s
– Balanced: 60 s
– Boost: 10 s
Alternating control:
Product description