Changing / Inspecting the AVR
The carbon brushes in conjunction with the AVR regulates power from the generator. If the
generator is overheated or overloaded, the AVR may be damaged and require replacement.
Remove generator cover
Remove AVR bolts
Disconnect AVR wire clip
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
Remove the 2 bolts holding the AVR.
Disconnect the wire clip.
1.
2.
3.
Changing / Inspecting the Carbon Brushes (Cont.)
Install new brush
Install new carbon brush with bolt.
4.
Connect AVR wires
Insert and connect the 2 wires from the AVR, be sure to connect
+ and – correctly.
5.
6.
Replace generator cover
Replace the back cover of the generator and secure with the
2 bolts.
TROUBLESHOOTING (CONTINUED)