USING THE GENERATOR (CONTINUED)
Connecting a load to the generator
NOTE: Be sure to attach devices to the correct receptacle (outlet).
●
120v devices can be directly connected to the 120v ONLY receptacles.
●
120v devices can be connected to the 120/240v receptacle using an appropriate adapter.
●
240v devices can ONLY be connected the 240v receptacle.
Plug in devices
Turn breaker on
Turn on connected devices
Plug in devices to the appropriate receptacle. When using
the generator in 120/240v mode, balance the load as closely
as possible. Placing more load on one side of the circuit will
reduce the breaker trip period.
Flip the circuit breaker up to the on position to allow power to
the receptacles.
Start or turn on appliances starting with the biggest loads
first.
1.
2.
3.
CAUTION: Do not connect 50Hz or 3-phase loads to the generator.
35
WARNING
- Only change the Voltage Selector Switch with the main AC Circuit Breaker
OFF. The generator can be seriously damaged if the Voltage Selector Switch is changed
with the breaker ON.
Voltage Selector Switch
Choosing the right power cord
This generator features Power Boost Technology, which gives the user
the ability to double the power in the generator for more heavy duty
applications.
The voltage selector switches the dual 120v AC windings of the generator
to produce “120V ONLY” or “120/240V”. If a 240V appliance is connected
to the 4-prong receptacle, the switch must be in the “120/240V” position.
If only 120V appliances are being connected to the generator select the
“120V ONLY” position to double the 120v amperage and automatically balance the load.
Long or thin cords can drain the power provided to an electrical device by the generator. When
using such cords, allow for a slightly higher rated wattage requirement for the electrical device. See
table below for recommended cords based on the power requirement of the electrical device.
TECHNOLOGY
POWER BOOST
DEVICE REQUIREMENTS
WIRE GAUGE BY LENGTH (ft.)
AMPS
WATTS (120/240V)
10
25
50
100
150
5
600/1200
18
16
14
12
10
10
1200/2400
16
14
12
10
8
15
1800/3600
14
12
10
8
6
20
2400/4800
12
10
8
6
4
25
3000/6000
10
8
6
4
4
30
3600/7200
8
6
4
4
NR
40
4800/9600
6
4
4
NR
NR
50
6000/1200
4
4
2
NR
NR
*NR = NOT RECOMMENDED