Changing / Inspecting the AVR
The carbon brushes in conjunction with the AVR regulates power from the generator. If the
generator is overheated or overloaded, the AVR may be damaged and require replacement.
Remove generator cover
Remove AVR bolts
Disconnect AVR wire clip
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
Remove the 2 bolts holding the AVR.
Disconnect the wire clip.
1.
2.
3.
53
Содержание DS4000S
Страница 2: ......
Страница 5: ......
Страница 19: ...19 Test handle pivot The handle should easily flip up and down after installation 1 ...
Страница 28: ...28 ...
Страница 34: ...34 ...
Страница 37: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 37 ...
Страница 49: ...TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator 49 ...
Страница 55: ...Replace generator cover Replace the back cover of the generator and secure with the 2 bolts 8 55 ...
Страница 56: ...WIRING DIAGRAM 56 ...
Страница 57: ...57 ...
Страница 63: ......
Страница 64: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX ...