Reconnect the AVR wire clip
Reconnect the wire clip.
7.
Disconnect wires from brush
Remove the 2 wires from the AVR on the carbon brush.
4.
Install new AVR
Install the new AVR with the 2 bolts.
5.
6.
Reconnect wires to brush
Insert and connect the 2 wires from the AVR. Make sure to
c and – correctly.
Changing / Inspecting the AVR (Continued)
TROUBLESHOOTING (CONTINUED)
66
Содержание DS13000DX
Страница 2: ......
Страница 5: ......
Страница 26: ...26 ...
Страница 35: ...35 ...
Страница 38: ...38 ...
Страница 45: ...45 4 Hours Total The number of hours the generator has been run in total ...
Страница 46: ...46 ...
Страница 49: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 49 ...
Страница 61: ...TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator 61 ...
Страница 67: ...Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts 8 67 ...