Changing / Inspecting the Carbon Brushes (Cont.)
Install new brush
Install new carbon brush with bolt.
4.
Connect AVR wires
Insert and connect the 2 wires from the AVR, be sure to connect
+ and – correctly.
5.
6.
Replace generator cover
Replace the back cover of the generator and secure it with
the 2 bolts.
TROUBLESHOOTING (CONTINUED)
64
Содержание DS13000DX
Страница 2: ......
Страница 5: ......
Страница 26: ...26 ...
Страница 35: ...35 ...
Страница 38: ...38 ...
Страница 45: ...45 4 Hours Total The number of hours the generator has been run in total ...
Страница 46: ...46 ...
Страница 49: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 49 ...
Страница 61: ...TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator 61 ...
Страница 67: ...Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts 8 67 ...
Страница 68: ...WIRING DIAGRAM 68 ...
Страница 69: ...69 ...
Страница 75: ......
Страница 76: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX REV DS13000DX 09102021 ...