CAUTION
: LPG must be shut off when using gasoline!
CAUTION
: Disconnect all electrical loads from the generator before attempting to
start!
WARNING
:
Operating the starter motor for more than 5 seconds can damage the
motor. If the engine fails to start, release the switch and wait 10 seconds before
operating the starter again.
Turn breaker ON/ Connect
The breaker is located on the right side of the front power
panel. Flip the breaker up to allow the power to flow to the
receptacles. Connect your devices to the receptacles on the
front panel. Start with the largest loads first.
7.
Turn engine switch to START
The key switch is located on the left side of the front power
panel. Insert the key and turn to the “START” position to
start the generator. Allow the key to return to the run
position once started.
5.
Open choke
Push the choke to the “OPEN” position as the engine warms up.
6.
33