Changing / Inspecting the Carbon Brushes
The carbon brushes in conjunction with the AVR regulates power from the generator. The
carbon brushes are wearable parts and should be inspected every 250 running hours.
Remove generator cover
Remove bolt from brush
Disconnect AVR wires
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
Remove the bolt holding the carbon brush.
Remove the two wires from the AVR on the carbon brush
1.
2.
3.
55
Содержание 991827K1
Страница 2: ......
Страница 5: ......
Страница 38: ...38 ...
Страница 41: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 41 ...
Страница 53: ...TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator 53 ...
Страница 59: ...Replace generator cover Replace the back cover of the generator and secure with the 2 bolts 8 59 ...
Страница 60: ...WIRING DIAGRAM 60 ...
Страница 61: ...61 ...
Страница 67: ......
Страница 68: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX ...