Duro Professional Series Скачать руководство пользователя страница 3

3

Cleaning the Pump

The following steps are for service and cleaning of the pump: 

1. Always disconnect unit from power supply before any servicing is performed.

2. Disconnect discharge piping and remove pump from sump/sewage basin. 

3. Submerse pump in a disinfectant solution (Clorox or chlorine) for at least one hour before disassembling pump. 

4. Detach volute from pump by removing the three bolts - DO NOT remove countersunk screws holding seal plate to stator housing or

warranty will be void. 

5. Gently pry volute from seal plate using a screwdriver. 

6. Clean impeller and inner volute using water. Do not use strong solvents (paint thinner, gasoline) which may damage the plastic. 

7. Re-attach volute after cleaning.  

Note: Do not remove the impeller from its shaft.

Figure 2 - Disassembly for Cleaning

Item #

Description

1

302701

Pump Volute (8097)

302728

Pump Volute (8098)

2

302702

Rubber Gasket

3

302703

Impeller (8097-78.4 MM)

302704

Impeller (8098-76.2 MM)

4

Pump Bracket

5

302705

Screw

6

302706

Mechanical Seal

7

Stator

8

302707

Lip Seal

9

Bearing

10

Rotor & Shaft

11

Pump Gasket

12

Bearing Housing

13 302708

Lock Nut

14 302709

Washer

15 302710

Rubber Seal

16

Top Cover

17

Screw

18

Grommet

19

Cord Screw

20

Power Cord

21

Capacitor

22

Handle

23

Oil Plug

Maintenance 
. The pump must be kept clean and free of debris.  
. The inlet screen prevents the passage of dirt and other solid material from entering 
the pump, but it can become overwhelmed.  
. Cleanings should occur often for pumps that run constantly. 
. Inspectors should make sure that the float is not tangled or jammed in one position.  
. A sump pump with a jammed float is useless because it will not sense when it 
should turn on and shut off.   
. The pump can be tested by pouring water into the pit to make sure it becomes 
activated and expels the water. 
. The homeowner should seek professional assistance if the pump does not activate. 
. Maintenance should take place annually, and when the home is sold. 
. When testing the pump, no one should ever reach into the pit. The float can be 
reached and manipulated with a household item such as a golf club (with a rubber 
handle) or anything else non-conductive that happens to be lying around.

Содержание Professional Series

Страница 1: ...hat a ground fault circuit be used Consult a licensed electrician for all wiring 3 Do not stand in water when connecting or disconnecting power cord from outlet 4 This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter 5 Do not pump flammable liquids with this pump as an explosion or fire could result 6 Vent sewage or septic tank according...

Страница 2: ... falling into the sump basin and possibly damaging the pump It may also prevent personal injury Electrical Information WARNING Risk of electrical shock this pump is supplied with a grounding type attachment plug To reduce the risk of electrical shock be certain that it is connected only to a properly grounded type receptacle The pump operates on a 115 volt 60 cycle AC single phase and has three pr...

Страница 3: ...06 Mechanical Seal 7 Stator 8 302707 Lip Seal 9 Bearing 10 Rotor Shaft 11 Pump Gasket 12 Bearing Housing 13 302708 Lock Nut 14 302709 Washer 15 302710 Rubber Seal 16 Top Cover 17 Screw 18 Grommet 19 Cord Screw 20 Power Cord 21 Capacitor 22 Handle 23 Oil Plug Maintenance The pump must be kept clean and free of debris The inlet screen prevents the passage of dirt and other solid material from enteri...

Страница 4: ...oting Checklist 1 Pump does not run or hums Pump plug and liquid level control plug not securely fastened together Push plugs together tightly Circuit breaker tripped or fuse blown Replace fuse 15 amp time delay fuse or reset breaker Liquid level control inoperative Test level control by plugging pump cord directly into wall outlet If pump operates float tether requires adjustments or should be re...

Страница 5: ...ricien licencié 3 Ne pilez pas dans l eau lorsque vous branchez ou débranchez le cordon d alimentation de la prise de courant 4 Ce produit devrait être connecté à une prise de courant à 3 broches avec mise à la terre équipé d un disjoncteur de fuite à la terre 5 N utilisez pas cette pompe pour pomper des liquides ininflammables car cela pourrait causer une explosion ou un incendie 6 Assurez vous q...

Страница 6: ...rizontale pour obtenir une performance maximale du clapet de non retour lorsqu il y a des matières solides Cela les empêchera de se loger dans le clapet et de le bloquer lorsqu il s ouvre ou se ferme Couvert du basin et ventilation Pour les applications relatifs aux eaux d égout sauf lors du pompage des eaux de puisard un couvercle étanche pour le basin et une ventilation adéquate sont obligatoire...

Страница 7: ...u de la surcharge 2 La pompe fonctionne sans jamais s arrêter Le contrôle du niveau de liquide est pris sur le rebord du bassin ou sur la pompe Libérez le flottant et repositionnez le de façon à se qu il ne soit plus obstrué en bougeant 3 Le moteur est en marche mais ne pompe pas assez ou du tout l eau Il y a des poches d air dans la pompe Faites opérer la pompe à travers de plusieurs cycles de mi...

Страница 8: ... place ni de transport en relation aux réparations ou remplacement de pièces ou d unités défectueuses et ne sera appliquée à aucun produit ayant subit des réparations ou des modifications sans l autorisation du fabricant Cette garantie n oblige en aucun cas le fabricant d être chargé de dommages indirects ou de passif de prévoyance résultant de la défaillance de n importe quel produit son bloc d a...