Introduction

This pump has been carefully packaged, inspected and tested to ensure safe operation and delivery. Before installing the pump, check to
see if any damage has occurred to the pump from rough handling. Notify the dealer from whom you purchased the pump if any damage
has occurred.

This sewage pump is suitable for pumping sewage, effluent, wastewater, groundwater and other non-explosive, non-corrosive liquids with
up to 2" (51 mm) solids. The pump includes a wide angle float switch that turns the pump on and off as the fluid level rises and falls.

Safety Instructions

The following safety rules should be followed to avoid serious injury or property damage:
Always remove the plug from the electrical outlet before servicing this pump.

1.

Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed
with your safety in mind. Be sure to comply with them.

2.

We recommend that a separate circuit be led from the home electrical distribution panel and properly protected with a fuse or a
circuit breaker. We also recommend that a ground fault circuit be used. Consult a licensed electrician for all wiring.

3.

Do not stand in water when connecting or disconnecting power cord from outlet.

4.

This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter.

5.  Do not pump flammable liquids with this pump as an explosion or fire could result.
6.

Vent sewage or septic tank according to local codes.

7.

Do not run this pump dry. Running your pump without water will damage the mechanical seal, reduce the life of the pump and void
the warranty.

8.

Do not touch metal motor housing for at least 30 minutes after pump has operated. A severe burn will result if pump is not allowed to
cool. Do not lift the pump by the electrical cord.

9.  This product does not require lubrication. A special oil has been put into the motor housing at the factory for lifetime lubrication of the

bearings. Use of any other oil can cause damage and void the warranty.

Installation Instructions

1. Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or gravel surfaces. 

2. Install pump in a basin of at least 16 inches (405 mm) diameter and 24 inches (610 mm) depth.

#51448EF    8/07

Submersible Wastewater Pump

Models DSBF300 & DSBW300

Operating & Installation Instructions

Содержание Professional Series

Страница 1: ...hat a ground fault circuit be used Consult a licensed electrician for all wiring 3 Do not stand in water when connecting or disconnecting power cord from outlet 4 This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter 5 Do not pump flammable liquids with this pump as an explosion or fire could result 6 Vent sewage or septic tank according...

Страница 2: ... falling into the sump basin and possibly damaging the pump It may also prevent personal injury Electrical Information WARNING Risk of electrical shock this pump is supplied with a grounding type attachment plug To reduce the risk of electrical shock be certain that it is connected only to a properly grounded type receptacle The pump operates on a 115 volt 60 cycle AC single phase and has three pr...

Страница 3: ...06 Mechanical Seal 7 Stator 8 302707 Lip Seal 9 Bearing 10 Rotor Shaft 11 Pump Gasket 12 Bearing Housing 13 302708 Lock Nut 14 302709 Washer 15 302710 Rubber Seal 16 Top Cover 17 Screw 18 Grommet 19 Cord Screw 20 Power Cord 21 Capacitor 22 Handle 23 Oil Plug Maintenance The pump must be kept clean and free of debris The inlet screen prevents the passage of dirt and other solid material from enteri...

Страница 4: ...oting Checklist 1 Pump does not run or hums Pump plug and liquid level control plug not securely fastened together Push plugs together tightly Circuit breaker tripped or fuse blown Replace fuse 15 amp time delay fuse or reset breaker Liquid level control inoperative Test level control by plugging pump cord directly into wall outlet If pump operates float tether requires adjustments or should be re...

Страница 5: ...ricien licencié 3 Ne pilez pas dans l eau lorsque vous branchez ou débranchez le cordon d alimentation de la prise de courant 4 Ce produit devrait être connecté à une prise de courant à 3 broches avec mise à la terre équipé d un disjoncteur de fuite à la terre 5 N utilisez pas cette pompe pour pomper des liquides ininflammables car cela pourrait causer une explosion ou un incendie 6 Assurez vous q...

Страница 6: ...rizontale pour obtenir une performance maximale du clapet de non retour lorsqu il y a des matières solides Cela les empêchera de se loger dans le clapet et de le bloquer lorsqu il s ouvre ou se ferme Couvert du basin et ventilation Pour les applications relatifs aux eaux d égout sauf lors du pompage des eaux de puisard un couvercle étanche pour le basin et une ventilation adéquate sont obligatoire...

Страница 7: ...u de la surcharge 2 La pompe fonctionne sans jamais s arrêter Le contrôle du niveau de liquide est pris sur le rebord du bassin ou sur la pompe Libérez le flottant et repositionnez le de façon à se qu il ne soit plus obstrué en bougeant 3 Le moteur est en marche mais ne pompe pas assez ou du tout l eau Il y a des poches d air dans la pompe Faites opérer la pompe à travers de plusieurs cycles de mi...

Страница 8: ... place ni de transport en relation aux réparations ou remplacement de pièces ou d unités défectueuses et ne sera appliquée à aucun produit ayant subit des réparations ou des modifications sans l autorisation du fabricant Cette garantie n oblige en aucun cas le fabricant d être chargé de dommages indirects ou de passif de prévoyance résultant de la défaillance de n importe quel produit son bloc d a...

Отзывы: