PF Conveyors | Installation, Operation & Maintenance Manual
25
u
Clearing Alarms
/ Čišćenje alarma
In the event the control displays an alarm code, turn the control switch to <STOP> (
), fix the condition per instructions below, disconnect the power, reconnect the power,
then turn the control switch to <RESET> (
). If the alarm does not clear, replacement of the control may be required.
U slučaju da upravljač prikaže kod alarma, okrenite prekidač upravljača u položaj Stop ( ), popravite stanje prema uputama u nastavku, isključite napajanje, ponovno
uključite napajanje, a zatim okrenite prekidač upravljača za resetiranje ( ). Ako se alarm ne poništi, možda će biti potrebna zamjena upravljača.
AL22
AL25
AL30
AL31
EN
The input voltage exceeded 240V
by 20%; an electrician must
check the power supply voltage.
The input voltage fell below 200V
by 20%; an electrician must
check the power supply voltage or
the wiring of the power cable.
The conveyor is jammed or experi-
encing mechanical problem; clear
the jam or repair the conveyor.
Overspeed error; replace the
gearmotor if recurring.
CR Ulazni napon premašio 240V za
20%; električar mora provjeriti napon
napajanja
Ulazni napon je pao ispod 200V za
20%; električar mora provjeriti napon
napajanja ili ožičenje kabela za
napajanje
Transportna traka se zaglavila ili ima
mehanički problem; očistiti zastoj ili
popraviti transportnu traku
Pogreška prekoračenja brzine;
zamijenite motor s reduktorom ako
se ponavlja
AL42
AL46
AL20
AL41
EN
The motor control cable (smaller
connector) or its wiring terminals
are improperly connected.
Power interrupted with the control
switch in the <START> position
(
).
Excessive current through the
control; check the cables between
the control and the motor for
breakage.
A read/write error has occured
within the control.
CR Upravljački kabel motora (manji
konektor) ili njegovi terminali ožičenja
nisu pravilno spojeni
Napajanje je prekinuto s kontrolnom
sklopkom u početnom položaju ( )
Prekomjerna struja kroz regulator;
provjerite jesu li kabeli između regula-
tora i motora prekinuti
Pogreška čitanja/pisanja unutar
kontrolera
AL21
AL28
EN
Main circuit overheat.
Open circuit on motor sensor
wire; electrician must check
wiring.
ES Pregrijavanje glavnog kruga
Prekinuti krug na žici senzora motora;
električar mora provjeriti ožičenje
If alarms will not clear, please refer to controller Operating Manual.
Ako se alarmi ne ponište, molimo pogledajte Priručnik za rad upravljača.