background image

15

15

15

SPOUTING

•  If shed has an optional downpipe kit, fi t end caps now.

•  Using six rivets per end, fi t and rivet end caps to each end of spouting and 

silicone end caps to ensure there are no leaks.

•  Nail assembled spouting to top of top plate, using four 30mm clouts as shown. 

(Note - spouting will overhang corner fl ashing by approx 20mm, spouting will 

always be on the lower top plate.)

•  Determine position of downpipe and mark a 30mm diameter hole in underside 

of spouting. (Note - hole needs to be centrally above corner fl ashing and can 

be at either end.)

•  Mark a 30mm diameter hole ensuring hole is as close as possible towards the 

corner fl ashing to allow enough clearance for downpipe cover fl ashing.

•  Cut out hole by drilling a few small holes then using tin snips to enlarge hole to 

correct size.

•  Fit dropper through hole and tighten nut on dropper. Silicone around top of 

dropper. Attach the hose to dropper with hose clip.

•  Position downpipe cover fl ashing over hose and rivet to wall cladding.

Содержание Fendalton

Страница 1: ...ASSEMBLY INSTRUCTIONS BASE SIZE 3 150m x 1 000m FENDALTON...

Страница 2: ...se electronic tools with care Use a Safety Trip Switch It is easier and quicker if this shed is erected by two people SELECT YOUR SITE Your shed must be level Achieve this by either levelling the grou...

Страница 3: ...1 000m 2 Lintel 45 x 45 H1 2 400m 1 Stud 45 x 45 H1 Yellow 2 295m 10 Stud 45 x 45 H1 Yellow 0 320m 3 Top Plate Packer 45 x 45 H1 3 150m 1 Nog 45 x 45 H1 0 910m 2 Nog 45 x 45 H1 0 990m 3 Nog 45 x 45 H1...

Страница 4: ...m 110 Clouts 50mm 15 Rivets 3 2mm 70 Roll of DPC 75mm wide 30m 1 Touch up paint and brush 1 DESCRIPTION LENGTH QTY PART DIAGRAM CHECKED Corner Flashing 2 364m 4 1001 Door Top Flashing 2 595m 1 1002 Do...

Страница 5: ...55m 1 Plywood 17mm treated 0 750m x 0 955m 1 Plywood 17mm treated 0 240m x 0 045m 2 Joists 45 x 45 H4 3 060m 1 Joists 45 x 45 H4 0 865m 3 Aluminium Door Step Flashing 2 395m 1 Floor Screws 40mm 50 Flo...

Страница 6: ...ller than the shed frame size which allows for a 10mm gap around the perimeter of the shed Concrete base to be a minimum of 80mm thick and at least 100mm thick around the perimeter Base should be at l...

Страница 7: ...x 990mm Nogs Select one 3150mm base plate Green one 3150mm top plate Red and four studs Yellow Lay out plates and four studs on a flat surface ensuring notches face outwards as shown Nail together us...

Страница 8: ...orway to top and bottom using the 240mm nogs to establish correct position Nail remaining two studs to inside of studs and top and bottom plates to make a double stud each side of doorway opening Nail...

Страница 9: ...ce the frame before rolling it over Position 910mm end wall nogs at correct height and nail in place The roof can slope either direction either falling to the front or falling to the back Determine wh...

Страница 10: ...of door studs as shown Using four 75mm screws screw 3060mm floor joist to back of front base plate Using twelve 75mm screws screw 865mm floor joists as shown Ensure frame is sitting level and check fr...

Страница 11: ...base and is positioned directly on the ground you wont need to attached DPC on the base plate Using ten 30mm clouts attach 75mm wide DPC membrane to each corner as shown DPC should be level with top...

Страница 12: ...filings between two sheets Remove all metal filings before riveting Carbon in pencils reacts with the Zinc Aluminium coating on steel Use ink to mark steel CLADDING DETAIL Side View CLADDING DETAIL O...

Страница 13: ...t screw right at the bottom of the sheet yet The top sheet will nish 848mm below the top of the framing and the second sheet nishes 1610mm down Position 2nd sheet underneath the first sheet repeat ab...

Страница 14: ...oor jamb flashing so top is level with underside of lintel Using tin snips knotch bottom of flashing around concrete or ply floor if required Attach using three 30mm clouts nailed to inside of stud an...

Страница 15: ...sition of downpipe and mark a 30mm diameter hole in underside of spouting Note hole needs to be centrally above corner flashing and can be at either end Mark a 30mm diameter hole ensuring hole is as c...

Страница 16: ...sure roofing screw is screwed through the top of the crest on corrugate profile See roof fixing pattern below Repeat using one 50mm clout predrill and nail roof sheet to upper top plate through rib of...

Страница 17: ...sing two rivets rivet ridge to corner flashing Push soft edge down into roof corrogations to prevent water penetrating under the ridge flashing Position barges as shown using six rivets rivet barge to...

Страница 18: ...hand side C 2 Steel locking bars D 2 SMALL PARTS BAG CONTAINING Guide clips door size dependent E 4 10 Door handle and fixing to suit F 1 Bottom rail stops and 6mm screws G 2 Faceplate and lock assemb...

Страница 19: ...sed across the opening to avoid gaps MEASUREMENTS Opening width As the standard door overlaps each side by 30mm or more the door should be 60mm wider than the 2400mm opening Opening height The door op...

Страница 20: ...with handle 80 80 HEADROOM REQUIREMENTS FOR DOORS Headroom A minimum of 410mm of headroom is required If the door is installed lower into the opening than shown below additional loss of door opening...

Страница 21: ...second bracket Re check levels then drill and fix as with first bracket PLACE DOOR ON BRACKET Do not cut plastic or packaging yet Using two persons and correct lifting techniques lift door onto the br...

Страница 22: ...h the axle forward in the slots toward the opening and tighten the nuts firmly without overtightening TENSION THE SPRINGS Ensure that the bottom rail is at the 3 o clock position as shown Ensure both...

Страница 23: ...that is level with the brackets B Slide four guide clips E into each guide C Position the bottom clip 200mm from the floor with the rest evenly spaced along the guide Position one guide over the edge...

Страница 24: ...ith top of locking bar Slide bars through the guide slot then back onto lock arms Screw on securely using the counter sunk screws O Ensure that locking bars do not protrude more than 20mm beyond guide...

Страница 25: ...Lock bar cover J WARNING Locking bar covers must be installed to prevent possible finger entrapment CLEAN UP Remove all swarf drill filings with a soft brush or rag Hose down roof and walls thoroughl...

Страница 26: ...caution b With a person at each end of the door hold the axle firmly with a large pip wrench Stillson at least 450mm long c Loosen the U bolt nuts at both ends and KEEP A FIRM GRIP ON WRENCH d Move th...

Страница 27: ...ercially available today However all exposed surfaces require some attention to guard against the premature onset of corrosion and any other harmful atmospheric effects In our atmosphere there are har...

Страница 28: ...ose the door should be about the same if door has an automatic opener put into manual mode before testing door If the door is difficult to operate in either direction up or down then check 1 that the...

Страница 29: ...ding fail to perform as specified above the liability of Riverlea Group Ltd shall in all cases be limited to replacing or repairing the defective product The balance of the original warranty will cove...

Отзывы: