background image

MK4A FLOOR

 

14

 

Step 4:

 

Nail  in each Floor  Board,  two 50mm  nails  in each 
end  and  two  into  Joists.  Measure  and  cut  Floor 
Flashing (A110) to fit in between Door Jamb Flash-
ings and nail in place using 50mm Clouts.

 

Step 1:  

Attach 

“ 

T

” 

locking handle with two 8x10mm 

screws TO R/H door (Door without the weather

-

strip). Slide hook onto square shaft and secure 
with a lock washer.

 

Hook

 

Lock Washer

 

Step 2:

 

Once doors are hung, position the Locking 
Stays so they slide into the Locking Brackets 
easily. Screw Locking Stays to Door Jamb.

 

SECURITY DOOR (Optional)

 

Step 3:

 

On the back of the left hand door, 
position  latch so that the hook on 
the door handle will be secure and 
go in and out easily. Rivet in place 
with four rivets.

 

Left Hand Door

 

Right Hand Door

 

Hook

 

Latch

 

Содержание SHEDS MK4A

Страница 1: ...Quality Built In ASSEMBLY INSTRUCTIONS MK4A BASE SIZE 4 210mm x 2545mm...

Страница 2: ...checklist If you are making your own floor refer to Raised Base Plate section now Do not attempt to build your shed in high winds Beware of sharp edges Protect your eyes and ears Use electric tools wi...

Страница 3: ...0 710 x 0 240m 1 Fixed Window Frame Glaze Beads Glass Louvre Window Frame Glass Over Panel Window Hardware Pack 2 830m 1 415m 1 415m 1 175m 1 Roof Sheets Flat Roof Sheet Clear Roof Panel Ridge Flashin...

Страница 4: ...Base Plate only YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW 1 810 45 45 45 45 1185 1185 1660 4210 45 45 45 FRONT WALL 45 45 45 45 1343 1343 1343 4210 45 45 45 BACK WALL 1900...

Страница 5: ...75mm nails per end Note If fitting a window there will be no centre stud on the window side Instead nail in a full length nog 2 405 in Gable or 4 120 in Back Wall using window studs 883 to get correct...

Страница 6: ...ack on a wall sheet means to use minimum nails hammered partly in to hold Wall Sheets in position Should a Wall Sheet need to be re positioned the nails can easily be prized out If a window is require...

Страница 7: ...lap as shown in fig 1 Ensuring Wall Sheet is flush with top of Top Plate tack in place Re peat with remaining three sheets Step 4 Nailing Off Nail one 30mm Clout each side of the Rib two per Pan into...

Страница 8: ...ill holes in each corner and nail Window Frame to framing using 50mm nails Step 4 If the Window is in the gable end tempo rarily position the Over Panel above Win dow Frame Following the same angle as...

Страница 9: ...tom Plates and hard against Stud Attach Door Jamb Flashing with three rivets into Rib on the outside and three 30mm clouts into studs on the inside Repeat with the other Door Jamb Step 3 Fit Corner Fl...

Страница 10: ...gs Also make sure the Wheels are cleaned of drill filings Re hang Doors Fit outer door stops Predrill a hole at each end of track into rib of cladding and screw outer door stops in using one Roofing s...

Страница 11: ...ed with pieces of timber from the packaging Step 3 Starting from the left hand end centralize Roof on Ridge Beam Ensure Roof is tight against end Wall Sheets predrill then nail one 50mm Clout through...

Страница 12: ...ews Screw one 50mm roofing screw into ridge beam through each rib on overlap one screw per sheet Mould the soft edge on the flashing down into the pans of the roof sheet to prevent roof leaks Step 4 C...

Страница 13: ...Rib MK4A FLOOR Step 1 Place shed in final position Check the diagonal measurements are the same and the shed is level before fitting Floor It is recommended that the shed is anchored down with either...

Страница 14: ...Door without the weather strip Slide hook onto square shaft and secure with a lock washer Hook Lock Washer Step 2 Once doors are hung position the Locking Stays so they slide into the Locking Brackets...

Страница 15: ...Plate This will stop water flowing in between the Base Plate and Floor The Floor should be made 15mm smaller than Base Size Note Although it is not essential fitting Damp Proof Course in between the B...

Страница 16: ...rried out in accordance with instructions below Should the cladding fail to perform as specified above the liability of Riverlea Group Ltd shall in all cases be limited to replacing or repairing the d...