2

IMPORTANT SAFETY INFORMATION

Please read these instructions carefully before use and retain for future reference.

•  Check the test leads, probes and case insulation before using. If you find any 

breakage or abnormality, or you consider the device is broken, stop using the 

device immediately.

•  When using the test probes, keep your fingers behind the finger protection 

ring.

•  Do not use the meter with the back cover open.

•  Select appropriate test range for measurements.

•  Ensure all inputs are less than the range selected otherwise it may cause 

electrical shock or meter damage.

•  Do not change the range selector position during voltage or current 

measurements.

•  Do not apply a voltage exceeding the marked voltage between COM terminal 

and ground.

•  Take caution when working voltages are above 60V DC or 30V AC rms.

•  Do not connect the meter to voltage signals when the range selector is on 

current, resistance, diode or continuity range.

•  When measuring current, each single measurement should be shorter than 10 

seconds. 

•  When a measurement has been completed, disconnect the testing probes 

from the circuit under test.

•  Replace the batteries as soon as the low battery indicator appears on the 

display.

•  Remove dead batteries from the meter or if it is not going to be used for a long 

time.

•  Never mix old and new batteries together, or different types of batteries.

•  Never dispose of batteries in a fire, or attempt to recharge ordinary batteries.

•  Before replacing the battery, turn off the meter and disconnect all the test 

probes.

•  To prolong battery life turn off the meter after use.

FUNCTIONS

Model

DCV

ACV

DCA

hFE

D03046

P

P

P

P

P

P

D03047

P

P

P

P

P

P

P

P

Содержание D03046

Страница 1: ...1 DIGITAL MULTIMETER Model D03046 and D03047 ...

Страница 2: ...terminal and ground Take caution when working voltages are above 60V DC or 30V AC rms Do not connect the meter to voltage signals when the range selector is on current resistance diode or continuity range When measuring current each single measurement should be shorter than 10 seconds When a measurement has been completed disconnect the testing probes from the circuit under test Replace the batter...

Страница 3: ...A Jack VΩmA Jack COM Jack hFE Socket Range Resolution Accuracy 200mV 100µV 0 5 of rdg 3D 2000mV 1mV 0 8 of rdg 5D 20V 10mV 200V 100mV 500V 1V 1 0 of rdg 5D OVERLOAD PROTECTION 220V rms AC for 200mV range and 500V DC or 500V rms for all ranges ...

Страница 4: ...Average responding calibrated in rms of a sine wave FREQUENCY RANGE 45Hz 450Hz OVERLOAD PROTECTION 500V DC or 500V rms for all ranges OVERLOAD PROTECTION 15 seconds maximum 220V RMS OVERLOAD PROTECTION F0 5A 500V and F5A 250V fuse MEASURING VOLTAGE DROP 200mV Range Resolution Accuracy 200µA 100nA 1 8 of rdg 2D 2000µA 1µA 20mA 10µA 200mA 100µA 2 0 of rdg 2D 5A 10mA 2 0 of rdg 10D ...

Страница 5: ...s to device or circuit being measured Turn on power of the device or circuit being measured voltage value will appear on Digital Display along with the voltage polarity DC CURRENT MEASUREMENT Red lead to VΩmA Black lead to COM for measurements between 200mA and 5A connect red lead to 5A jack with fully depressed Set RANGE switches to desired DCA position Open the circuit to be measured and connect...

Страница 6: ...sed figure 1 will be shown TRANSISTOR hFE MEASUREMENT Set RANGE switch to the hFE position Determine whether the transistor is PNP of NPN type and locate the Emitter Base and Collector leads Insert the leads into the correct pins of the hFE socket The meter will display the approximate hFE value at the condition of base current 10μA and VCE2 8V AUDIBLE CONTINUITY TEST Red lead to VΩmA Black lead t...

Страница 7: ...st always as a result of operator error F500mA 500V for mA terminal and F5A 500V for 5A terminal Clean the meter with a clean soft cloth Do not use any chemicals abrasives or solvents that could damage the meter Max display LCD 3 digits 1999 count 0 5 high Polarity Automatic indicated minus assumed plus Measure method Double integral A D switch implement Sampling speed 2 times per second Over load...

Страница 8: ...fe it must be treated as Waste Electrical Electronics Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local authority for details of recycling schemes in your area Made in China PR2 9PP Man Rev 1 0 ...

Отзывы: