![Duratech HD-8 V Series Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/duratech/hd-8-v-series/hd-8-v-series_operating-instructions-manual_2541467074.webp)
66
HD-8 SERIES V
O P E R A T I N G I N S T R U C T I O N S
Table 6.2 Troubleshooting the electronic
governor’s engine mode
4.
Checking the ENGINE MODE operation of the electronic governor. If the tub mode controls function
correctly after following the tub mode trouble shooting check list, then follow the calibration instructions
on page 30 of this manual. If the tub will not rotate, proceed to trouble shooting table 6.2.
PROBLEM
CAUSE
REMEDY
1. The tub will not
rotate, and the sensor
light is not lit.
1. The sensor gap is out of adjustment.
2. There is a broken wire on the wiring harness.
3. The sensor is faulty.
4. The sensor light bulb is faulty.
5. The electronic governor is faulty.
1. Readjust the sensor gap to 3/32". This is
roughly the thickness of a nickel.
2. Repair or replace the wiring harness.
3. Test and replace the sensor as necessary.
4. Replace the sensor light bulb
5. Replace the electronic governor.
2. The tub will not
rotate, and the sensor
light is lit.
1. The tub limit knob is set fully counter-clockwise.
2. The manual hydraulic valve is in the neutral position.
3. The electronic governor is faulty.
1 Adjust the tub limit knob clockwise.
2 Engage the manual hydraulic valve.
3. Replace the electronic governor.
Содержание HD-8 V Series
Страница 2: ...Clearing the Way for a Better Tomorrow ...
Страница 4: ...Clearing the Way for a Better Tomorrow ...
Страница 72: ...64 HD 8 SERIES V O P E R A T I N G I N S T R U C T I O N S figure 5 13 fixed hammer pattern ...
Страница 87: ...79 HD 8 SERIES V O P E R A T I N G I N S T R U C T I O N S Clearing the Way for a Better Tomorrow ...
Страница 91: ...83 HD 8 SERIES V O P E R A T I N G I N S T R U C T I O N S Clearing the Way for a Better Tomorrow ...
Страница 93: ...85 HD 8 SERIES V O P E R A T I N G I N S T R U C T I O N S Clearing the Way for a Better Tomorrow ...