DG65M-R62
Troubleshooting
Problem
Cause
Solution
Generator will not start
Fuel tank is empty
Refill gasoline to proper level
Defective or dirty spark plug
Replace spark plug
An electrical device is plugged
into the generator
Unplug device and restart generator
Generator will not start or it
starts but runs roughly
Oil level is too low
Refill oil to the proper level
Place generator on a flat, level surface
Choke isn’t in proper position
Adjust choke
Spark plug has loose wire
Tighten wire connecting spark plug
Generator starts but then
immediately shuts off
Fuel tank is too low or empty
Refill gasoline to proper level
Oil level is too low
Refill oil to the proper level
Place generator on a flat, level surface
Generator isn’t supplying
enough power or the
generator is overheating
Generator is overloaded
Confirm electrical device plugged into
your generator is single-phase 60 Hz.
Confirm total requirements of all devices
plugged into your generator do not
exceed the power limit of your generator.
Refer to “Stay within your generator’s
power limit” section of manual (page 23).
Cooling holes are blocked
Check the cooling holes on the side
panel and bottom of the generator. Clear
away any mud, water, paper or other
debris.
Note
: Troubleshooting continues on following page
Generator has no AC output Cable isn’t properly connected
Reattach all connections