M-500
Measured points
A
B
1.
Internal superior of the oven close of the thermostat cable.
160
2.
Next the motor of the revolving.
60
3.
External
lateral of the oven beside the transformer
.
60
4.
External
central superior of the oven
60
5.
Insulation of white cable next the superior interlock.
65
6.
Insulation of the black grey that come from the transformer primary
rolling.
65
4.7
Operation without load
The microwaves oven must be operated without load
during the most time permitted by timer.
The oven could not suffer no damage. Any device of
safety will have to act.
4.8
Supervision device
To curt-circuit the supervisor device of the door. Supply
the device with nominal voltage with the door closed. The
door opening will provoke the automatic power off of the
microwaves generator.
4.9
Protection against electric chock (miniature standard finger)
The standard finger miniature (figure 101 of the IEC 335 -
- 25) cannot touch live parts when applied without
appreciable force in device parts that are accessible only
when the oven is operated in normal use.
4.10 Cutting parts
The device will not have present cutting partes that can
bring risk to the user during a normal operation or
maintans.
4.11 Insulation
Do not have be used as insulation the following materials:
ü
wood, cotton, silk, ,commom paper, with staple, hygroscopic.
Содержание M-500
Страница 5: ...Fl 3 3 Esc S E M 500 1 05 72424 02 ...
Страница 18: ...M 500 6 ELECTRICAL SCHEME 6 1 MAIN PCB 7 SILKTOP AND SOLDERS 7 1 MAIN PCB 8 EXPLODED VIEW ...
Страница 22: ......