38
––– E 7 –––
CONNECTION ERROR
Cause
•
Bad connection between AF-100 and DC-545
•
Feed PCB unit is defective
•
Main PWB unit is defective
Problem detected
1. Can not confirm connection between AF-100 and DC-545 while machine is operating.
––– E 8 –––
ELEVATOR ERROR
Cause
•
Elevator upper switch is defective
•
Elevator lower switch is defective
•
Elevator motor is defective
•
Paper level sensor is defective
•
Feed PCB unit is defective
•
Main PWB unit is defective
Problem detected
1. Elevator was not detected at elevator upper switch, elevator lower switch, or paper level sensor after the specified
time (* seconds) after the command to operator the elevator was issued.
* 10 seconds when rising at start-up, 3.5 seconds when paper is being fed, 9 seconds when going down at shut-down
NOTE :
• When this error occurs there is a possibility that the screws pressing on the spring, or the elevator
up and down switch are damaged.