Sensor range for use with GS300Mc
HCF100 Refrigerant Gas Sensor
CO233A CO Sensor
SGM595 Methane or LPG Sensor
CO100AR CO Sensor
Technical Specification
Gas(es) Detected
Carbon Monoxide
Dimensions
Width 100mm
|
Height 100mm
|
Depth 60mm
Display
6 Colour Digital Display
Sensor Technology
Electrochemical
Settings
Preset to TWA and STEL Standards
Output Signal
4-20mA
Sensor range
0-300ppm
Working Temperature
-20°C to +50°C
Autosetting
Yes
Protective Rating
IP65
Approvals
EN50270 & EN45544-1-3 Compliant
Technical Specification
Gas(es) Detected
Freons (Inc R134A, R404A, R407C, R410A)
Dimensions
Width 76mm
|
Height 150mm
|
Depth 58mm
Display
N/A
Sensor Technology
Semiconductor
Settings
N/A
Output Signal
4-20mA
Sensor range
0-300ppm
Working Temperature
-10°C to +60°C
Autosetting
Yes
Protective Rating
IP55
Approvals
EN50270 & EN45544-1-3 Compliant
Technical Specification
Gas(es) Detected
Carbon Monoxide
Dimensions
Width 100mm
|
Height 100mm
|
Depth 60mm
Display
N/A
Sensor Technology
Electrochemical
Settings
Preset to TWA and STEL Standards
Output Signal
4-20mA
Sensor range
0-300ppm
Working Temperature
-15°C to +40°C
Autosetting
Yes
Protective Rating
IP55 (Enclosure) IP65 (Sintered Head)
Approvals
BS EN50291 Compliant
Technical Specification
Gas(es) Detected
Methane and LPG
Dimensions
Width 73mm
|
Height 108mm
|
Depth 57mm
Display
N/A
Sensor Technology
Catalytic
Settings
N/A
Output Signal
4-20mA
Sensor range
5% to 20% LEL
Working Temperature
-10°C to +60°C
Autosetting
Yes
Protective Rating
IP55
Approvals
EN50194 Compliant
IP65
IP55
4-20mA
4-20mA
4-20mA
4-20mA
8
8
8
Colour Change
Digital Display
IP55
IP55
Propane
Freons
Methane
CO
CO