background image

8

3308120.XXX GENESIS AIR FILTRATION SYSTEM

OPERATING

INSTRUCTIONS

1.

GENERAL INSTRUCTIONS

A. Read your Control Systems Operating Instructions care-

fully before attempting to start your air conditioner.

B. The 3308120.XXX Genesis Air Filtration System is

designed to allow the unit to direct the air flow through the
RV’s duct system; or, by opening a slide control the air
will be discharged directly out from the return air cover.
1. Slide the slide handle towards the front of the RV to

divert the air into the duct system.

2. Slide the slide handle to the rear of the RV and the air

will discharge out the return air cover.

G. Use Aluminum foil tape (not provided) to seal the ends of

the foam divider to the sides of the opening. Make sure
the area behind the flange on the ceiling template is

sealed. See Figure 9.

FIG. 9

Use Aluminum Foil Tape To Seal the
Foam Divider To The Sides of 14-1/4"
x 14-1/4" (±1/8") Ceiling Opening

Make Sure To Seal
Behind Flange

Route wires
through Slot

Catch Flange In Groove Of
Return Air Cover

H. Install the slider in the  return air cover and raise it to the

ceiling template. Route the wires from the return air
cover through the template slot leaving about 3” of wire
in between. Place the front of the return air cover against
the ceiling and slide towards the rear. The flange on the
ceiling template will catch in the groove on the return
cover. Adjust the position (right to left) and  install the
front two screws. Start and tighten the remaining screws
to hold it in place. Connect together the DC wires (3
Black - negative and 3 Red - positive) from the supply,
control box and filter indicator. See figure 9.

Note: Number 10 cabinet screw can be used to replace
the two front screws, and pull the plastic return air cover
to the ceiling  when the ceiling material is hard.

1. If solar panel is installed see instructions pack

aged with solar panel option.

I.

Tighten the screws holding the return air cover. Slide the
filter from the right side (looking toward the RV front) over
the wires. Make sure the wires are above the filter and are
out of its way.

J.

Place grill on return air cover and snap in place. Decal is
on end over circuit board.

K. Place slide handle through slots in grill into the slide

posts. Handle will fit in either direction. See Figure 10.

C. The “CLEAN FILTER” bulb will blink as a reminder to

clean/change the air filter every 60 days. If in dusty
conditions, the filter should be checked bi-weekly and
clean/changed if needed.
1. To clean the filter, remove the dust using a vacuum
cleaner. Wash filter with a mild detergent, rinse with
clean water and allow to dry.
NOTE: Replace filter annually. See your Duo Therm
Dealer for replacement filter. Filter part numbers are
stamped on filter frame.

2.

To reset the “CLEAN FILTER” reminder:
a. Depress the gray button “FILTER RESET” on the

decal of the grill. The Light will blink 3 times to indicate
a successful reset. See Figure 11.

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN
FILTER

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN

FILTER

FIG.11

Push To Reset

Light

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN
FILTER

Ceiling
Template

Foam
Divider

Slide

Filter

Return
Air
Cover

FIG. 10

Grill

Slide
Handle

Содержание GENESIS 3308120.XXX

Страница 1: ...dge Ontario CANADA N3H 2N7 519 653 4390 For Service Center Assistance Call 800 544 4881 3308120 XXX GENESIS AIR FILTRATION SYSTEM FOR 57XXX SERIES 59XXX SERIES 600XXX SERIES 620XXX SERIES 630XXX SERIES AIR CONDITIONERS HEAT PUMPS USED WITH 3109226 005 ELECTRONIC CONTROL KIT 3109407 001 ELECTRONIC CONTROL KIT 3107541 009 ANALOG CONTROL KIT 3107541 017 ANALOG CONTROL KIT 3107546 008 ANALOG CONTROL K...

Страница 2: ...2 3308120 XXX GENESIS AIR FILTRATION SYSTEM NOTES ...

Страница 3: ...cessorieslikeA Eoutdoorpatioandwindowawnings willreduceheatgainbyremovingthedirectexposureto the sun They also add a nice area to enjoy company during the cool of the evening C Condensation Note The manufacturer of this Genesis Air Filtration System will not be responsible for damage caused by condensed moisture on ceilings or other surfaces Air contains moisture and this moisture tends to condens...

Страница 4: ...rconditioner two thirdsfromfrontofRVandcentered from side to side It is preferred that the air conditioner heat pump be installed in a relatively flat and level roof sectionmeasuredwiththeRVparkedonalevelsurface Improper installation may damage equip ment could endanger life cause serious in jury and or property damage WARNING 3 AIR DISTRIBUTION SYSTEM SIZING DESIGN The Installer of this air condi...

Страница 5: ...ns packaged with the system options before beginning the installation B ROOFANDCEILINGOPENINGPREPARATION 1 A 14 1 4 x 14 1 4 1 8 opening must be cut through the roof and ceiling of the RV This opening must be located between the roof and reinforcing members C DUCTSIZINGREQUIREMENTSASFOLLOWS NOTE Duct sizes listed are inside dimensions Min Max 1 Duct Depth 2 00 2 1 2 2 Duct Width 8 00 10 00 3 Total...

Страница 6: ...will damage the roof gasket Note If center duct system is being used be sure to installductadaptertothebottomofthebasepan before unitisplacedoveropening Ductadapter3100342 XXX and 3100262 XXX can be used Alternate methods of duct connection are available for installation however they must be approved in writing by Dometic C Locate the foam divider and insert it corner to corner in the 14 1 4 x 14 ...

Страница 7: ...peoffofthedividerandplace it on the center of the rear edge of return air opening on the ceiling template See figure 7 FIG 8B Penguin Models Lay Control Box Flat On Top Of Ceiling Template Control Box Two Screws Vehicle Front FIG 8A Brisk Air Models Mount Control Box on Edge To The Flange on Ceiling Template Control Box Three Screws Vehicle Front FIG 7 Foam Divider Ceiling Template Center And Stic...

Страница 8: ... from the supply control box and filter indicator See figure 9 Note Number 10 cabinet screw can be used to replace the two front screws and pull the plastic return air cover to the ceiling when the ceiling material is hard 1 If solar panel is installed see instructions pack aged with solar panel option I Tighten the screws holding the return air cover Slide the filter from the right side looking t...

Отзывы: