MAINTENANCE 

 

Dunham-Bush Evo-Lite radiant panels are essentially maintenance free, with no moving parts. Panel surfaces can 

be washed with mild cleaner or detergent followed by rinsing. Strong, abrasive or mechanical cleaning should not 

be used. If panels or accessories become damaged, they can be replaced after isolating, draining and 

disconnecting from pipework or adjacent panels. 

 

 

 

 

SPARES/SERVICE 

 

 

 
PLEASE WRITE THE DETAILS OF RADIANT PANELS HERE. 

These details will be required when ordering spares for your Dunham-Bush radiant panels 

 

STYLE AND No. OF TUBES 

 

                                                                                                                                                              

BL DRAWING OR ORDER No. 

 

                                                                                                                                                              

DATE OF INSTALLATION 

 

                                                                                                                                                              

 
 

 

 

 

 

Spare parts/service – Please contact our office, contact information shown below. 

Manufacturer reserves the right to change any product specification without notice. 
Dunham-Bush Ltd, Downley Road, Havant, Hants, PO9 2JD 
 

 

Sales and Technical Support 

Spare Parts and Service 

Tel:  023 9247 7700     Fax:  023 9245 3601 

Tel:  023 9247 7700     Fax:  023 9245 3601 

Email:  [email protected] 

Email:  [email protected] 

 

 

Page 8 of 8 

Содержание Evo-Lite Style CG

Страница 1: ...h may also be shown on the BL drawing DESCRIPTION Evo Lite Style CG comprises aluminium alloy sheet panel bonded to an extruded aluminium channel profile copper tube carrying the hot water is mechanic...

Страница 2: ...suspected at the time of delivery Preparation Evo Lite Style CG radiant panels are intended for horizontal installation within a standard 600mm ceiling grid hence it is important to liase with other t...

Страница 3: ...Diagram 3 Typical section detail for installation Style CG 4T shown 2T similar Diagram 4 Suspension point locations for Evo Lite Style CG Page 3 of 8...

Страница 4: ...sing panel joint clips and M5 nuts provided Refer to Diagram 6 5 Expansion panels should be fitted every 6m of straight panel run and are supplied with expansion hoses fitted in place of the straight...

Страница 5: ...Diagram 6 Installation detail of Evo Lite Style CG standard joint Diagram 7 Installation detail of Evo Lite Style CG expansion joint Page 5 of 8...

Страница 6: ...s for leaks Refer to Table 2 for test and working pressures 4 Balance the water flow rate through the panel to accepted practice to achieve the specified flow rate 5 Leave this document and any layout...

Страница 7: ...el runs Refer to Diagram 2 for typical arrangements in a panel run Dunham Bush will prepare complete baseboard layout drawings for approval which can be used to co ordinate materials and installation...

Страница 8: ...WRITE THE DETAILS OF RADIANT PANELS HERE These details will be required when ordering spares for your Dunham Bush radiant panels STYLE AND No OF TUBES BL DRAWING OR ORDER No DATE OF INSTALLATION Spare...

Отзывы: