background image

•  This  appliance  is  using  flammability  refrigerant. 

So  never  damage  the  cooling  pipework  during 
the transportation.  

•  Locate  the  unit  away  from  direct  sunlight  and 

sources  of  heat  (stove,  heater,  radiator,  etc.). 
Direct sunlight may affect the acrylic coating and 
heat 

sources 

may 

increase 

electrical 

consumption. 

Extreme 

cold 

ambient 

temperatures  may  also  cause  the  unit  not  to 
perform properly.  
 

•  Avoid locating the unit in moist areas. 

 

•  Plug the unit into an exclusive, easily accessible 

plug  socket.  Any  questions  concerning  power 
and/or  earthing  should  be  directed  towards  a 
qualified  electrician  or  an  authorized  products 
service centre.  

•  The  appliance  must  be  installed  to  all  electrical, 

connections  in  accordance  with  state  and  local 
codes. 

• 

IMPORTANT:  HIGH  HUMIDITY  CLIMATE. 

During  periods  of  high  humidity,  some 
condensation may appear on outside surfaces of 
glass  door.  This  condensation  will  disappear 
when  humidity  levels  drop.  For  prevention,  it  is 
advisable  to  install  the  appliance  with  sufficient 
ventilation  in  a  dry  and/or  an  air-conditioned 
place. 

 

NOTE:  The  appliance  must  be  positioned  so 

that  the  plug  is  accessible.    Release  the 
electric  cord.  Move  your  cabinet  to  its  final 
location.  Do  not  move  your  Cabinet  while 
loaded  with  wine.  You  might  distort  the  body. 
The  wine  cellar  should  be  installed  in  a 
suitable  place  in  order  to  avoid  touching  the 
compressor with hand. 

Attention 

 

Store wine in sealed bottles. 

 

Do not overload the cabinet. 

 

Do not open the door unless necessary. 

 

Do not cover shelves with aluminum foil or any 
other shelf material which may prevent air 
circulation. 

 

Should the Wine cooler/Beverage cooler be 
stored without use for long periods it is 
suggested, after a careful cleaning, to leave the 
door ajar to allow air to circulate inside the 
cabinet in order to avoid possible formations of 
condensation, mold or odors. 

 

BUILT-UNDER INSTRUCTIONS  

Make  sure  your  installation  does  not  block  the  front 
ventilation  grille.

 

The  unit  is  designed  to  fit  under 

worktops  between  820  and  890mm  in  height. 
Remove  the  adjustable  ventilation  grille  screws  and 

slide it to the required height. Tighten  the screws to 
lock the grille in position.  
If the unit is fully integrated  to  be installed for fitting 
kitchen plinth, make sure that the ventilation gaps in 
the  plinth  are  at  least  300  square  centimeters  and 
remove  the  ventilation  grilles,  so  that  warm  air  can 
disperse  unhindered.  Otherwise  the  appliance  must 
work  harder,  resulting  in  an  increase  in  electricity 
consumption.  

NOTE:

  When  pushing  the  appliance  into  the  niche, 

make  sure  that  the  mains  cable  does  not  get 
trapped.  

FULLY INTEGRATED BUILT-IN-COLUMN 

INSTRUCTIONS  

The  unit  door  seals  the  installed  unit  almost 
completely,  so  an  air  vent  must  be  provided  in  the 
base of the housing. Warmed air must be conducted 
via  the  ventilation  shaft  to  the  rear  wall  of  the 
housing  and  then  expelled  upwards.  The  ventilation 
channels  should  measure  at  least  200  square 
centimeters in cross-section.  

WARNING: 

To  ensure the  proper functioning  of the 

appliance,  air  vents  should  never  be  blocked  or 
covered.  

BUILT-IN CABINET INSTRUCTIONS  

Make sure your installation does not block the front 

ventilation grille.

 

And be sure the door will open and 

close properly in the chosen location.  

YOU CAN FIND THE DETAILED 

 

INSTALLATION DRAWING IN THE 

 

ATTACHMENT 

 

 
ELECTRICAL CONNECTION  
WARNING: 

Improper  use  of  the  grounded  plug 

can result in the risk of electrical shock. If the power 
cord  is  damaged,  have  it  replaced  by  a  qualified 
electrician or an authorized service center.

 

 

All electrical work should be carried out by a suitably 
qualified  and  competent  person  in  accordance  with 
local and national safety regulations.  

Check  that  the  voltage  marked  on  the  product 
corresponds with your supply voltage.  

Connect  this  appliance  to  a  separate,  at  least  13A 
circuit.  

Connection should  be made via a  suitable switched 
socket which is easily accessible. For extra safety it 
is advisable to install a residual current device (RCD) 
with a trip current of 30mA.  

Have  the  receptacle  and  the  circuit  checked  by  a 
qualified  electrician  to  ensure  that  the  socket  is 
grounded correctly.  

Note:  

In locations where there is frequent lightning, 

it is advisable to use surge protectors.

  

Содержание DAUF-46.145DB

Страница 1: ...WINE CABINET INSTRUCTION MANUAL 2020 V 1 Model Two section models DAUF 46 145DB DSS ...

Страница 2: ...ar of the appliance To disconnect the appliance grip the plug and pull it from the wall outlet Never pull by the cord WARNING Please keep the appliance away from substance which can cause ignition Do not operate the appliance in the presence of explosive and or flammable fumes Do not place the appliance or any of its part near an open flame cooking or other heating appliance Do not operate the app...

Страница 3: ...nce Failure to do so can result in back or other injury Never clean appliance parts with flammable fluids These fumes can create a fire hazard or explosion And do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance The fumes can create a fire hazard or explosion Do not connect or disconnect the electric plug when your hands are wet It is r...

Страница 4: ...terior liner offer lifetime performance and stability The black liner prevents excessive light from damaging the maturity process Full glass or seamless stainless steel framed glass door with stainless steel handle Beech shelves allow for maximum convenience and flexibility to accommodate various size bottles Security lock system with keys for particular items only Passive humidity control system ...

Страница 5: ...0mm in height Remove the adjustable ventilation grille screws and slide it to the required height Tighten the screws to lock the grille in position If the unit is fully integrated to be installed for fitting kitchen plinth make sure that the ventilation gaps in the plinth are at least 300 square centimeters and remove the ventilation grilles so that warm air can disperse unhindered Otherwise the a...

Страница 6: ...s shown above with two screws and flat washers provided 3 Install the door gasket Note All parts removed must be saved to do the reinstallation of door ADJUSTING THE REMOVABLE SHELVES Lift the nylon buckle of left rail and press down the nylon buckle of right rail in the same time then the shelf can be pulled out from the rail compartment To install back the shelf line up both left and right rail ...

Страница 7: ...to the left side 6 Install the door hinge first as shown in Figure 3 and install the lower door hinge as shown in Figure 4 7 Lift the door as shown in Figure 4 Firstly insert the lower hinge into the corner fittings align the mounting holes and insert the hinge shaft into the hinge hole in position Then cover back the Hinge buckle The installation of the lower part of the door is completed 8 Insta...

Страница 8: ...n touch the lighting mark to turn on off the LED light or change the light color into 3 different colors green blue red The lighting will stay on until it is automatically turned off TEMPERATURE DISPLAY WINDOW The temperature is displayed in digital format which is the best way to be read out The display shows the set temperature when you are setting the temperature and it will display the real te...

Страница 9: ...ocated as well the specific type of models Our appliances are in line with international standards for such appliance and in line with the latest technical developments But please remember that the noise of the compressor and the coolant circulating in the system is unavoidable DEFROSTING HYGROMETRY VENTILATION Your unit is designed with an automatic defrost system During the Off cycle the evapora...

Страница 10: ...rfaces that can come in contact with food and accessible drainage systems Wash the inside surfaces with a warm water and baking soda solution The solution should be about 2 tablespoons of baking soda to a pint of water Wash the shelves with a mild detergent solution Wring excess water out of the sponge or cloth when cleaning any area of the controls Wash the outside cabinet with warm water and mil...

Страница 11: ...GUIDE ALL MODELS PROBLEM POSSIBLE CAUSE REMEDY Appliance does not operate Appliance is not connected to a power supply The appliance is turned off The circuit breaker tripped or a blown fuse Connect the appliance Switch on the appliance Switch on circuit breaker or replace fuse Appliance is not cold enough The temperature is not set correctly The ambient temperature could require a higher temperat...

Страница 12: ...ircuit 88 indicates that the connection wire of control board is failed Check the upper temp sensor Check the upper temp sensor Check the evaporator sensor Check the evaporator sensor Check the lower temp sensor Check the lower temp sensor Check the connection wire of control board The alarm sounds and the temperature display flashes Has the appliance door been open for longer than 60 seconds If n...

Страница 13: ...e manufacturer 9 Parts such as light removable shelves or plastic 10 Any spoilage or damage to wines or any other contents incidental or consequential to possible defects of the unit NOTE The warranty clauses and specifications are subject to change without notice ...

Отзывы: