BUILT-UNDER INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille.
The unit is designed to fit under
worktops between 820 and 890mm in height. Remove
the adjustable ventilation grille screws and slide it to the
required height. Tighten the screws to lock the grille in
position.
If the unit is fully integrated to be installed for fitting
kitchen plinth, make sure that the ventilation gaps in the
plinth are at least 300 square centimeters and remove
the ventilation grilles, so that warm air can disperse
unhindered. Otherwise the appliance has to work harder,
resulting in an increase in electricity consumption.
NOTE:
When pushing the appliance into the niche, make
sure that the mains cable does not get trapped.
FULLY INTEGRATED BUILT-IN-COLUMN
INSTRUCTIONS
The unit door seals the installed unit almost completely,
so an air vent must be provided in the base of the
housing. Warmed air must be conducted via the
ventilation shaft to the rear wall of the housing and then
expelled upwards. The ventilation channels should
measure at least 200 square centimeters in cross-
section.
WARNING: To ensure the proper functioning of the
appliance, air vents should never be blocked or covered.
BUILT-IN CABINET INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille.
And be sure the door will open and
close properly in the chosen location.
You can find the detailed installation drawing
in
the attachment.
ELECTRICAL CONNECTION
WARNING:
Improper use of the grounded plug can
result in the risk of electrical shock. If the power cord is
damaged, have it replaced by a qualified electrician or an
authorized service center.
All electrical work should be carried out by a suitably
qualified and competent person in accordance with local
and national safety regulations.
Check that the voltage marked on the product
corresponds with your supply voltage.
Connect this appliance to a separate, at least 13A circuit.
Connection should be made via a suitable switched
socket which is easily accessible. For extra safety it is
advisable to install a residual current device (RCD) with
a trip current of 30mA.
Have the receptacle and the circuit checked by a
qualified electrician to ensure that the socket is grounded
correctly.
NOTE:
In locations where there is frequent lightning, it is
advisable to use surge protectors.
Do not connect the appliance to the mains electricity
supply by an extension lead. Extension leads do not
guarantee the required safety of the appliance (e.g.
danger of overheating).
The appliance must not be connected to an inverter and
must not be used with a plug adapter as these can cause
damage to the appliance’s electronic unit.
The cord must rest securely behind the appliance and not
be allowed to lie or hang unprotected.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
INSTALLING THE HANDLE
IMPORTANT: Do not overtighten the screws & do not
use power tools to install the handle. Overtighten screw
causes glass breakage.
DESIGN 1
–
Locate the handle
○
,1 over the fixing pins
○
,3 of the door
and using the supplied allen key, tighten the securing
grub screws
○
,2 to fix the handle.
DESIGN 2
–
1. Remove the door gasket
○
,1
on the side you wish to
install the handle - you can see two designated holes
for handle installation.