WARRANTY

KEEP THIS WARRANTY

Model 

 _______________________________

Serial No. 

 ____________________________

Date Purchased 

 _______________________

Keep receipt for warranty verification.

REGISTER YOUR PRODUCT AT WWW.FACTORYBUYSDIRECT.COM

FACTORY BUYS DIRECT LIMITED WARRANTIES

New Products

Standard Warranty:

 Factory Buys Direct warrants this new product and any parts thereof to be free from 

defects in material and workmanship for a period of one (1) year from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with 

Factory Buys Direct’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 

the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 Factory Buys Direct warrants factory reconditioned products and any parts thereof to be 

free from defects in material and workmanship for a period 30 days from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with Factory 

Buys Direct’s warnings and instructions. No return will be authorized. Parts will be provided to repair the product.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 

this warranty, the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 

and only when installed by a qualified installer in accordance with all local codes and instructions furnished 

with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and 

an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap-

proved by Factory Buys Direct. Warranty parts must be obtained through authorized dealers of this product 

and/or Factory Buys Direct who will provide original factory replacement parts. Failure to use original factory 

replacement parts will void this warranty.
Traveling, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 

repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 

responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 

improper installation, lack of proper maintenance, tampering or alteration(s).
This is Factory Buys Direct’s exclusive warranty, and to the full extent allowed by law; this express warranty 

excludes any and all other warranties, express or implied, written or verbal and limits the duration of any 

and all implied warranties, including warranties of merchantability and fitness for a particular purpose to one 

(1) year on new products and 30 days on factory reconditioned products from the date of first purchase. 
Factory Buys Direct makes no other warranties regarding this product.
Factory Buys Direct’s liability is limited to the purchase price of the product and Factory Buys Direct shall not 

be liable for any other damages whatsoever under any circumstances including direct, indirect, incidental, 

or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 

incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

Factory Buys Direct

500 Brown Industrial Parkway

Canton, GA 30114

1-855-607-6557

Содержание FDF400RT-ZC Series

Страница 1: ...l switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING Thisappliance isequippedfornatural and propane LP gas Field conversion is not pe...

Страница 2: ...roper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by...

Страница 3: ...rate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Failure to follow these instructions will void the warranty Onlyaqualifiedinstaller service agent or local gas supplier may install and service this product WARNING Keep the appli ance area clear and free from combustiblematerials gasoli...

Страница 4: ...part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water SAFETY 10 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater 11 Operating heater above elevations of 4 500 feet could cause pilot outag...

Страница 5: ...r a Installing testing or replacing gas piping or b Connecting installing testing repairing or servicing equipment that is experienced in such work that is familiar with all precau tions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The OD...

Страница 6: ...monwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts the gas cock must be a T handle type The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length 1 Remove top inner pack 2 Tilt carton so that he...

Страница 7: ...eproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as poss...

Страница 8: ...lation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not ...

Страница 9: ...ents or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 from the front top or sides of the heater in high traffic ar...

Страница 10: ...prohibited CAUTION To avoid gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator Thisisnormal Whenthein let connection fitting is inserted and tightened this plunger will be pushed back by the fitting making all of the adjustments for the gas being supplied...

Страница 11: ...ack as the fitting is installed Make sure the type of gas being used is correct Check to make sure the connection fitting is in the correct inlet on the regula tor Refer to Connecting to Gas Supply page 14 If you are using natural gas and the pilot will not light see Troubleshooting page 26 Metal Cap Metal Cap DO NOT REMOVE Yellow Natural Gas Plunger Install Gas Fitting Here 2 Apply thread sealant...

Страница 12: ...wall should not be less than 12 see Figure 5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialstooverlap the firebox front WARNING Do not allow combustibleornoncombustible materialstocoveranynecessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front...

Страница 13: ...ning Use dimensions shown in Figure 7 for the rough opening If installing in a corner use dimensions shown in Figure 9 for the rough opening The height is 23 1 4 which is the same as the wall opening above 2 Locate standoff brackets in the hardware bag Remove screws from the top of the firebox Install brackets with screws as shown in Figure 10 3 Carefully set fireplace in front of rough opening wi...

Страница 14: ... acceptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas supply Follow all local codes WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator WARNING Do not over tighten gas connections WARNING For natural...

Страница 15: ...nting Down External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sediment Trap Tee Joint Pipe Nipple Gap 3 Minimum reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incom ing gas pressure heater regulator damage could o...

Страница 16: ...re isaleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping sys tem Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize sup...

Страница 17: ...ling logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Install pins on log 1 into the two slots in the bracket attached to rear wall see Figure 16 2 Install pins on log 2 into the two slots in left side of the middle bracket see Figure 16 and Figure 17 3 Install pins on log 3 into the two slots in right side of the middle bracket see Figure 1...

Страница 18: ...e receiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control AAA 2 or 3 Remote Receiver AA 4 Note Quantity depends on model of remote control Ignitor Unscrew ignitor cap and install a AAA battery with the pointing out Replace cap Figure 21 Installing Batteries in Remote Control and Rece...

Страница 19: ... YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Open damper or window to vent smell This will only last a few hours 1 STOP Read the safety information abo...

Страница 20: ...ver box to the OFF position then back to the ON position Note Please wait one minute after shut ting off heater to allow the control valve to reset before starting again 13 Make sure heater screen is in place before operating heater 14 If heater will not operate follow the in structions To Turn Off Gas To Appliance and call your service technical or gas supplier CAUTION Do not try to ad just heati...

Страница 21: ... dam aged the slide switch on the receiver can be used to operate the heater Note When batteries are replaced the learning process above must be repeated LEARN REMOTE OFF ON Figure 23 Receiver Slide Switch Learn Button Key Settings ON Operates unit to on position manually operated solenoid ON OFF Operates unit to off position manually operated solenoid OFF MODE Changes unit from manual mode to the...

Страница 22: ...key The LCD screen will display the set temperature for 3 sec onds then flash the set temperature for 3 seconds then LCD screen will default to display the room temperature To Change The Set Temperature 1 Press and hold the SET key until the desired set temperature is reached The LCD screen set numbers will increase from 45 to 99 then restart over at 45 2 Release the SET key The LCD screen will di...

Страница 23: ...w tipping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Approx 3 6 Above Top of Logs More Than 8 Above Top of Logs Approx 3 6 Above Top of Logs More Than 8 Above Top of Logs Figure 30 Correct Burner Flame Pattern Figure 31 Incorrect Burner Flame Pattern ...

Страница 24: ...ust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Repeat steps 3 and 4 CARE AND MAINTENANCE WARNING Turn off heater and let cool before servicing CAUTION You must keep control areas burner and circulating airpassagewaysofheaterclean Inspecttheseare...

Страница 25: ...ixture Wipe the cabinet to remove dust CARE AND MAINTENANCE Figure 33 Pilot Inlet Air Hole LOGS If you remove logs for cleaning refer to Installing Logs page 17 to properly replace logs Replace log s if broken or chipped dime size or larger Back of pilot shown for clarity Pilot Air Inlet Hole Natural Gas Burner Propane LP Gas Burner Thermocouple Pilot Air Inlet Hole Ignitor Electrode SERVICE HINTS...

Страница 26: ...C Bypass pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified installer should light the appliance Refer to the correct flame pattern as illustrated on page 23 All flame patterns should be safely inside the product If for any reason they are not stop use of th...

Страница 27: ...e 2 Fully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 24 or replace ODS pilot assembly 5 Check inlet gas pressure or replace inlet gas regulator 6 Turn control knob to PILOT position 7 Contact local propane LP gas company ODS pilotlightsbutflame goes out whe...

Страница 28: ...place gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 26 1 Contact a qualified service technician to remove foreign matter 2 Locate and correct all leaks see Checking Gas Connec tions page 15 Slight smoke or odor during initial operation 1 Residues from manufactur ing process 1 ...

Страница 29: ...Propane LP models Heater shuts off in use ODS operates 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local gas supplier 3 Clean ODS pilot see Care and Maintenance page 24 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 26 2 Control valve is defec...

Страница 30: ...www factorybuysdirect com 200372 01A 30 PARTS MODEL FDF400RT ZC 9 8 10 12 11 13 15 18 14 6 1 2 3 4 16 7 5 17 PILOT OFF ON RE MO TE OF F ON LEA RN TEMP 19 ...

Страница 31: ... 01 AAA Battery 1 3 161333 01 AA Battery 4 Not a field replaceable part REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement parts call Customer Service toll free at 1 855 607 6557 for referral information When ca...

Страница 32: ...ost of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap proved by Factory Buys Direct Warranty parts must be obtained through authorized dealers of this product and or Factory Buys Direct who will provide original factory replacement parts Failure to use original factor...