Main Controller Replacement Instructions:

TSC-6/18 and PBC-6/18

12. 

Touch / select the top right “info” button (circled 

exclamation point) on the display. Touch / select 

the upper left “User” icon. Touch / select the 

“System Status” button and verify input levels 

and output loads are functioning as expected.

13. 

Exit to the PIN code screen and program the 

prior recorded recipe names and set points if 

they are different from the new Main Control 

Module Assembly’s recipe settings.

14. 

Allow the unit to run until Preheat cycles are 

complete and the Oven and Proofer are in 

“READY” modes. Verify Proofer RH is active 

via proofer door glass visual. Verify Oven and 

Proofer temperatures reasonably correlate with 

other temperature measurement equipment.

8. 

Tilt up and slide back the control panel. Replace 

the Top 2 screws and tighten all 8 screws on 

both sides. Verify the Duke logo screen or the 

“gray” button start screen is properly displayed.

NOTE:

 

Verify wiring is not trapped or 

visible under the controls panel after fully 

slid into position.  

9. 

Turn OFF and turn back ON the left side power 

switch while watching the control display. 

Record the software version identifier (Example 

“A005.88F”) at the bottom of the Duke Logo 

screen. Repeat Off / On cycle if the software 

version I.D. is missed during the automatic logo 

screen view.

10. 

From the “gray” screen, select either the Oven 

icon or an Oven recipe and verify the Oven 

lights turn ON and verify fault messages are not 

displayed in the top tool bar of the display. Go to 

the Troubleshooting Guide if Oven lights do not 

turn ON.

11. 

Select either the Proofer icon or a Proofer recipe 

and verify the Proofer lights turn ON and verify 

fault messages are not displayed in the top tool 

bar of the display. Go to the Troubleshooting 

Guide if Proofer light do not turn ON.

NOTE

:  The units controls and sensors are 

high precision and should not require 

to be recalibrated. Up to 10% variances 

between the measurement device and 

the units controls are most probably due 

to measurement equipment accuracy 

and not the units control system. Contact 

Duke Service should any sensor calibration 

questions arise.  

Содержание TSC-6/18M

Страница 1: ...l Module Assembly For ELC0017 1 PCB TSC TSCM OR ELC0017 7 PCB TSC PBC 512418 Strap Disposable Wrist ESD This manual is Copyright 2019 Duke Manufacturing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co CAUTION Please read this manual completely before attempting to install operate or service this equipment DUKE...

Страница 2: ...middle of the oven NOTE The Main Control Module Assembly is 12VDC supplied only and is isolated from dangerous or high voltages by inner safety cover inside the controls cavity behind the exterior controls panel 4 Loosen but do not remove the bottom and rear screws on the slide out Remove top left and top right screws 5 Slide the control panel forward and tilt down the control panel 6 Connect ESD ...

Страница 3: ... Do not remove 2 Center Nuts Remove Outer Nuts INSTALLING NEW CONTROL 3 To prevent static cling between the display and overlay lightly dust the display glass with baby powder or talc powder Gently remove powder by brushing with a cosmetic brush as shown below Do not wipe the display with hands or any cloth as this may scratch the glass Additionally do not put any powder on the overlay 5 Repack th...

Страница 4: ...rt screen is properly displayed NOTE Verify wiring is not trapped or visible under the controls panel after fully slid into position 9 Turn OFF and turn back ON the left side power switch while watching the control display Record the software version identifier Example A005 88F at the bottom of the Duke Logo screen Repeat Off On cycle if the software version I D is missed during the automatic logo...