Installation and Operation of: iNTERSECT

III.  KITCHEN MINDER SETUP

Requirements: 

•  Kitchen Minder 1 v6.01 or higher, or
•  Kitchen Minder 2 v6.01 or higher
•  PC Minder v6.01 or higher

Laptop

25’ Cat5E 

Ethernet Cables

NOTE:

iNTERSECT supports up to 2 Kitchen Minder COM channels for up to 6 PHU’s, or a maximum of 48 wells.

A. 

Connection to Kitchen Minder

 

a. Install up to 2 Cat5e cables from master PHU units to iNTERSECT unit.

 

b. Power to Kitchen Minder should be placed in the OFF position 

 

c. Connect the first Cat5e cable to Kitchen Minder port labeled “COM1”.  

 

    Connect the other end of this cable to the iNTERSECT port labeled

 

     “KM COM1”. Fig A-1

 

d. Connect the second Cat5e cable to Kitchen Minder port labeled  

 

    “COM2”. Connect the other end of this cable to the iNTERSECT port   

 

    labeled “KM COM2”.

 

e. Power to the iNTERSECT should be placed in the ON position and  

 

    power to each of the PHU’s should be placed in the OFF position. 

Fig A-1

B. 

Configure PHU’s in Kitchen Minder

 

a. Configure PHU’s in PC Minder per user instruction manual provided for that equipment.

IMPORTANT

: For Duke PHU model HS2, it is required to 

NOT

 modify the temperature set points as 

prescribed and defined in the ICC Product Profiles file. If hold temperatures other than 165F, 200F, or 210F 

are used, the PHU will respond with a “BAD FCST” (Bad Forecast) error on the PHU timer bar displays.

C. 

Map KM Ports to Ethernet PHU’s

 

a. Connect laptop computer to any port labeled  “ETHERNET PHU” of the iNTERSECT.  Unplug any 

 

    Ethernet PHU to make room if necessary.

 

b. Disable all other wired or wireless connections, on your laptop, except wired connection to

 

     iNTERSECT,  on your laptop.

 

c. Open a web browser on the laptop and navigate to 

http://172.16.10.20/

.

Содержание INTERSECT

Страница 1: ...ing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co CAUTION Please read this manual completely before attemptin...

Страница 2: ...oided could result in death or serious injury and or equipment damage Indicates hot surface which if not avoided could result in minor or moderate injury TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTION...

Страница 3: ...hang over edge of table or counter The following warnings and cautions appear throughout this manual and should be carefully observed Turn the unit off disconnect the power source and allow unit to c...

Страница 4: ...ned by the driver delivery person Unpack and check for any damage which was not evident on the outside of the shipping container Check for concealed damage The carrier must be notified within fifteen...

Страница 5: ...ll Bits Phillips Screw Driver Wire Cutters Wire Ties D NETWORK REQUIREMENTS Duke iNTERSECT requires an internet connection to maintain software updates to iNTERSECT new PHU product recipe information...

Страница 6: ...he cardboard box to open c Remove the iNTERSECT and mounting bracket from the box d Drill 4 mounting holes into selected mounting surface Use mounting bracket as template e Attach mounting bracket to...

Страница 7: ...e or supplier adminis trator of the restaurant s network management to contact Duke ViSOR Support Fig B 1 C Ethernet PHU Connection a Install a Black Cat5e Ethernet cable from each PHU to the iNTERSEC...

Страница 8: ...the iNTERSECT port labeled KM COM2 e Power to the iNTERSECT should be placed in the ON position and power to each of the PHU s should be placed in the OFF position Fig A 1 B Configure PHU s in Kitchen...

Страница 9: ...d in PC Minder i To perform the drag and drop click and hold the PHU name for example PHU1 2x4 in the figure below and move the mouse over the warmer name then release A rectangle should appear next t...

Страница 10: ...et Switch NOT INCLUDED Duke Intersect P N 118322 ICC Kitchen Minder Restaurant Router or Internet Gateway 3rd PHU OR Expansion Switch for up to a total of 4 PHUs Intersect Connections PHU 1 PHU 2 PHU...

Страница 11: ...Network Diagram Internet Internet Internet Switch VLAN Firewall ISP POP Powered by AWS Duke Intersect BK Store Premise Duke Connected Equipment Platform 443 Outbound Secure Tunnel Firmware Updates An...

Страница 12: ...N Part No DUKE iNTERSECT 118322 Mounting Bracket 118745 25Ft Cat5 Cable 118027 Power Cord 118437 Expansion Kit 118757 B MANUAL UPDATES Visit https phuconfig dukemfg com for the most current version of...

Отзывы: