background image

Installation and

Operation Manual

P/N 118738

REV D 01/23/2020

This manual is Copyright © 2020 Duke Manufacturing Co. All rights reserved.  

Reproduction without written permission is prohibited. Duke is a registered  

trademark of the Duke Manufacturing Co.

CAUTION:

Please read this manual completely before attempting 

to install, operate or service this equipment

WARNING

: Cancer and Reproductive Harm -

 

www.p65warnings.ca.gov                      

Содержание INTERSECT

Страница 1: ...ing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co CAUTION Please read this manual completely before attemptin...

Страница 2: ...oided could result in death or serious injury and or equipment damage Indicates hot surface which if not avoided could result in minor or moderate injury TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTION...

Страница 3: ...hang over edge of table or counter The following warnings and cautions appear throughout this manual and should be carefully observed Turn the unit off disconnect the power source and allow unit to c...

Страница 4: ...ned by the driver delivery person Unpack and check for any damage which was not evident on the outside of the shipping container Check for concealed damage The carrier must be notified within fifteen...

Страница 5: ...ll Bits Phillips Screw Driver Wire Cutters Wire Ties D NETWORK REQUIREMENTS Duke iNTERSECT requires an internet connection to maintain software updates to iNTERSECT new PHU product recipe information...

Страница 6: ...he cardboard box to open c Remove the iNTERSECT and mounting bracket from the box d Drill 4 mounting holes into selected mounting surface Use mounting bracket as template e Attach mounting bracket to...

Страница 7: ...e or supplier adminis trator of the restaurant s network management to contact Duke ViSOR Support Fig B 1 C Ethernet PHU Connection a Install a Black Cat5e Ethernet cable from each PHU to the iNTERSEC...

Страница 8: ...the iNTERSECT port labeled KM COM2 e Power to the iNTERSECT should be placed in the ON position and power to each of the PHU s should be placed in the OFF position Fig A 1 B Configure PHU s in Kitchen...

Страница 9: ...d in PC Minder i To perform the drag and drop click and hold the PHU name for example PHU1 2x4 in the figure below and move the mouse over the warmer name then release A rectangle should appear next t...

Страница 10: ...et Switch NOT INCLUDED Duke Intersect P N 118322 ICC Kitchen Minder Restaurant Router or Internet Gateway 3rd PHU OR Expansion Switch for up to a total of 4 PHUs Intersect Connections PHU 1 PHU 2 PHU...

Страница 11: ...Network Diagram Internet Internet Internet Switch VLAN Firewall ISP POP Powered by AWS Duke Intersect BK Store Premise Duke Connected Equipment Platform 443 Outbound Secure Tunnel Firmware Updates An...

Страница 12: ...N Part No DUKE iNTERSECT 118322 Mounting Bracket 118745 25Ft Cat5 Cable 118027 Power Cord 118437 Expansion Kit 118757 B MANUAL UPDATES Visit https phuconfig dukemfg com for the most current version of...