background image

PHOTON SYSTEM 

 Installation Guide v8.0 - pag.1

 

 

PHOTON SYSTEM

 

Installation Guide

 

(rel. 8.0)

 

 

 

 

Fig. 1 

General description of the system

 

The Photon system by Deitech, in its basic configuration, is 

made of two bars absolutely identical (Fig. 1), placed at the two 
ends  of  the  area  to  be  controlled  thus  creating  an  “infrared 
barrier”;  the  bars  are  connected  with  just  one  cable  to  a  hub  
(Fig.  2),  that,  placed  in  the  Control  Unit,  controls  the  whole 
system. The bars are used for both transmission and reception 
of the beams,  work in couple  and  exists  in  different  versions: 
from 50 to 200 cm height, with or without heather, with maximum 
range 25, 50 and 80 meters. They have all the same design; are 
made of an aluminium body with a black polycarbonate cover 
and two caps of the same colour. 

On the “ROTAX” cap  (Fig. 3) you can 

find  the  connection  terminals  and  the 
ROTAX  system  for  the  orientation  of 
the  beams.  On  the  “NUMBER”  cap  
(Fig. 4) there is the selector for the ID 
number to assign to the bar and, in the 
models with heater, the terminal blocks 
for heater power supply. Through a four 
wires  cable  plus  shield,  the  barriers 
(from ROTAX cap) will be connected to 
the hub; the connection could be a star 
or in series so that it can easily adjust 
to 

the 

different 

installation 

requirements. 

The hub controls the correct operation of the barriers, allows the configuration of the system 

and concentrate the connexion with the control panel. The hub will manage up to a maximum 
of four couples, that can be installed even in the same area and the beams will not interfere 
between themselves. The four couples can be of different heights and different range but the 
bars of each couple must be the same. For each couple the hub will allow to set different 
operation parameters (see HUB-TC Manual for details) and manage single stand-by inputs. 

The alarm output toward the control panel are different for each couple, while the technical 

outputs (tamper, disqualification, failure) are common for all the couples managed by the hub. 

If the installation will require more than four couples, then more hub are needed. 

 

THE BARS

 

It’s absolutely fundamental to install the couple of bars properly, each couple must be placed in order 

to protect the passage through which an intruder could pass. In order to determine the correct mounting 
height of the bar, it must be taken into consideration that the first beam (and the last) is placed at about 
20 cm from the end of the bar and that between the other beams there are 25 cm. The barrier can be 
placed upside down to connect the hub either from above or from below, but it is mandatory that each 
couple is installed in the same position. All the Photon barriers have a patented system that allows a 
correct horizontal alignment of the beams (ROTAX). This system will enable the installer to install them 

Fig. 2 

 hub-tc 

Fig. 3 – rotax cap 

Fig.4 – number cap 

Содержание Photon System

Страница 1: ...configuration of the system and concentrate the connexion with the control panel The hub will manage up to a maximum of four couples that can be installed even in the same area and the beams will not...

Страница 2: ...om the hub a standard 4 wire cable two for power supply 0 75 mm2 2 for the serial communication 0 22 mm2 and shield The number of possible connection typologies is quite wide and for each one of that...

Страница 3: ...n Cable connection inside the bars The cable connection is made in the following steps 1 Prepare the cable Fig 8 A B 2 Insert the cable in the cable gland Fig 9 3 Fold the cable shield backwards and l...

Страница 4: ...w of contacts on which a jumper is inserted in the position corresponding to the address to assign to the bar Fig 11 Fig 11 Addressing of the NOT HEATED version HEATED version due to the presence of t...

Страница 5: ...intend to manage the stand by separately They can also be connected all together in order to have not separate stand by for the different couples When the barriers are in stand by the beams are not a...

Страница 6: ...nected bars are detected by the software 1 2 3 4 5 6 7 8 If some bar is not detected check that the addresses on the bars and the connections are correct then make again the test Do not go to the next...

Страница 7: ...ssion is in the direction on the red sign on the ROTAX Fig 17 5 Do the same operation on the other bar of the couple 6 Connect the TBS tester to dedicated plug inside the ROTAX cap Fig 16 7 Turn on th...

Страница 8: ...nnected to the dedicated plug inside the ROTAX cap of the bars Fig 26 It is sufficient to connect to any of the bars or to the HUB to check the whole system Though a selector you can select the couple...

Страница 9: ...and archive everything happens in the system The software allows you to store all system events with the time in which they occurred This allows you to keep track of them for many months Through a que...

Страница 10: ...PHOTON SYSTEM Installation Guide v8 0 pag 10 SUMMARY TABLES Fig 23...

Страница 11: ...SISTEMA PHOTON manuale d installazione pag 11 Fig 24...

Страница 12: ...G WILL CAUSE LOSS OF WARRANTY RIGHTS AS WELL AS LOSS OF THE DECLARED IP LEVEL CABLE GLAND MOUNTING MANDATORY THE SUPPLIED CABLE GLANDS ENSURE THE IP65 GRADE IT S MANDATORY FOR THE INSTALLER TO MOUNT T...

Страница 13: ...SISTEMA PHOTON manuale d installazione pag 13...

Страница 14: ...SISTEMA PHOTON manuale d installazione pag 14 HUB TC...

Страница 15: ...the wire to be used for a connection to a maximum distance of 50 mts from the power supply In any case the external diameter of the connection cable must not be more than 6 8mm MODEL VOLTAGE COURRENT...

Страница 16: ...SISTEMA PHOTON manuale d installazione pag 16...

Страница 17: ...SISTEMA PHOTON manuale d installazione pag 17...

Страница 18: ...ighten only one of two fixing screws a and leave moving possibility to the second screw to ensure the profile of barrier free to expand contract for thermal expansion The bar must not bend under any c...

Страница 19: ...SISTEMA PHOTON manuale d installazione pag 19...

Страница 20: ...SISTEMA PHOTON manuale d installazione pag 20 MANUALS AND SOFTWARES AVAILABLE ON WEBSITE www duevi eu INSTALLER SUPPORT support duevi eu...

Отзывы: