User Menu 

(only in ADVANCED mode) Special menu with control panel options, only for 
Master users. In this menu it is possible, for example, to set date and time, 
manage other users, bypass zones, etc. 

Monitor (zone) 

A zone sets as MONITOR, when violated, cause only the buzzer sound on 
keyboards and key readers (not sirens) for 30 seconds. 
Function useful for example in case you want to protect an external area, and 
just be warned when you are at home. 

Panic (wired) 

Press a dedicated button to start the siren sound for a fixed time of 30 
seconds, in order to draw attention. The panic vocal call and SMS are send (if 
enabled). 

Partialization 

Special arming mode of control panel, it exclude a group of zones. In this way 
a part of the protected area will not be monitored by the system and it will be 
possible to move inside this area without alarm even if the system is armed 

BUS device 

Device connected to control panel by a 4 wires cable (BUS RS485) (usually 
keyboards, key readers and expansion boards) 

PreAlarm 

Only for PARTIAL armings. 
At the start of alarm, the siren sounds at low level – for a programmed time – 
and then continue at high level. 
During the pre-alarm no SMS or vocal call are sent. 

Sensor 

Device for violation detection with different technologies (glass breaking, 
intrusion, door opening, ecc.) 

Sounds 

On keyboards some sounds are disabled – with variable time – when the user 
or installer make some operation: 

 

simple operations 

 sounds disabled for about 30 seconds 

 

programming or event queue 

 sounds disabled for 10 minutes 

The disabled sounds are: 

 

entry and exit sounds 

 

pre-alarm 

 

monitor and technologic 

 

maintenance 

LCD / OLED 
keyboard 

Keyboard provided with display LCD / OLED, buttons and LEDs and with which 
the user/installer interact with the alarm system. The keyboard allows the 
control panel programming. 

Entry Time 

It is possible to program some zone – when violated – to cause siren sound 
only after a certain time. 
Useful for example if the control panel is far from entry door and it is 
necessary to go near to it to disarm the system. 

Exit Time 

It is possible to set a time that allow to arm the system and exit from the 
building without generate alarm. 

Output 

There are four outputs on control panel, which are activated according to 
some combined event (ex.: to switch on a lamp in case of alarm or to activate 
a phone dialler) 
BASE mode: the outputs are pre-programmed 

Содержание CE818

Страница 1: ...1 Made in Italy CE818 User Manual 14 07 M1 5 1 H2 0 F1 41 S1 41 ENG...

Страница 2: ...a GSM or PSTN communicator optional to provide you an intelligent remote alarm signalling In case of alarm the phone communicator will inform you with a vocal message or SMS allowing you even when you...

Страница 3: ...485 Wired electronic keys reader CHT Transponder electronic key ASIG ASC ABASC Wired magnetic contacts DIRF DIRRPV DDT S Single and double technology indoor sensors E Wall DIRFE barriers MOSKITO F Out...

Страница 4: ...to the dialler User Code Six digit code used to access to alarm system using the keyboard Coercion This function allow to obtain a silent alarm signalling in case you are forced to disarm the system...

Страница 5: ...programmed time and then continue at high level During the pre alarm no SMS or vocal call are sent Sensor Device for violation detection with different technologies glass breaking intrusion door open...

Страница 6: ...time the zones set for this behavior This function is useful for example to allow the access only in certain areas without disarm the system service staff Zone A zone manage all the sensors connected...

Страница 7: ...oard allow to control your alarm system visualize the system status functions and other alerts arm and disarm user management visualize system events and alarms ALWAYS CHECK ON DISPLAY YOUR CORRECT OP...

Страница 8: ...the user violates a zone not set as Patrol R the control panel will detect alarm When leaving the Patrol user can include again the bypassed zones or it is possible to set an auto rehabilitation time...

Страница 9: ...ame privileges can arm in Total Partial and Disarm the system ADVANCED mode At each user can be combined one electronic key up to 16 users If the user is set as MASTER its key will arm and disarm with...

Страница 10: ...10 BASE MODE...

Страница 11: ...0 30 in case of opened doors Fixed Entry time 30 Fixed Alarm time 120 Fixed Alarm cycles From same zone 4 Fixed In same arming cycle 10 Fixed Vocal calls 1 for each telephone number Only alarm call if...

Страница 12: ...GSM module installed PARTIAL ARMING To arm the system in PARTIAL mode pass twice a CHT key over a key reader A confirming beep is emitted and the GREEN LED lights solid on key reader To arm it is als...

Страница 13: ...ed Sound alerts One beep to confirm disarming In case entering by zone 1 before disarm a beep series signals the Entry time 30 s LED on LET 485 OFF Control panel outputs Output 1 or 2 arming type chan...

Страница 14: ...key reader is normally OFF The LED lights on to signals events LED OFF ON BLINKING Red Disarmed Off TOTAL armed Alarm memory number of last violated zone at disarming for 60 seconds Green Disarmed Off...

Страница 15: ...15 ADVANCED MODE...

Страница 16: ...30 Changeable Alarm time 120 Changeable Alarm cycles From same zone 4 Fixed In same arming cycle 10 Fixed Vocal calls 1 for each telephone number Only alarm call if GSM BUS PSTN installed Arming modes...

Страница 17: ...emitted after that the system is active 3 A beep series for about 30 seconds exit time are emitted after that the system is active TOTAL arming Active zones All the zones enabled in Total mode but byp...

Страница 18: ...ch on 4 A beep series for about 30 seconds exit time are emitted after that the system is active 3 A beep series for about 30 seconds exit time are emitted after that the system is active PARTIAL 1 ar...

Страница 19: ...reader and F3 button on keyboard switch on 4 A beep series for about 30 seconds exit time are emitted after that the system is active 3 A beep series for about 30 seconds exit time are emitted after...

Страница 20: ...entering by a delayed zone before disarm a beep series signals the Entry time 30 seconds Visual alerts Key reader LED off Keyboard button solid on Control p outputs Output 1 INS changes status Output...

Страница 21: ...ntrol panel function is enabled when a door or window remain opened the keyboard alerts by blinking the button red If with an opened door you try to arm the system the control panel will alert with a...

Страница 22: ...required 2 Digit the user code followed by 3 Alert is enabled disabled The Alert status on off is shown by the blue button on keyboard 12 32 01 06 10 Disarmed User Code User Code Digit the User Code 9...

Страница 23: ...long the menu options the button to enter and or confirm a choice the button to cancel and or delete PSTN REMOTE CODE Change the Remote Code For PSTN communication for GSM Remote Code see COMBY GSM BU...

Страница 24: ...his user type has not access to User menu Guest Guest user has limited access and can arm only as programmed by Master or Installer Guest user can disarm the system only if enabled This user type has...

Страница 25: ...e tamper line or pass a CHT key the name of the user or key will appear on display OFF To exit from test press the button OUTPUT TEST Verify outputs and wired siren working Outputs Test Wired siren To...

Страница 26: ...y OFF The LED lights on to signals events LED OFF ON BLINKING Red Normal working TOTAL armed Alarm memory at disarming for 60 s Green Normal working PARTIAL 1 armed One or more opened zones at system...

Страница 27: ...ber only alarm SMS COMMANDS XXXX Remote Code Note attention to spaces insert them as indicated on table Action Command Total arming XXXX instot Partial 1 arming XXXX inspar1 Partial 2 arming XXXX insp...

Страница 28: ...28...

Отзывы: