User Menu
(only in ADVANCED mode) Special menu with control panel options, only for
Master users. In this menu it is possible, for example, to set date and time,
manage other users, bypass zones, etc.
Monitor (zone)
A zone sets as MONITOR, when violated, cause only the buzzer sound on
keyboards and key readers (not sirens) for 30 seconds.
Function useful for example in case you want to protect an external area, and
just be warned when you are at home.
Panic (wired)
Press a dedicated button to start the siren sound for a fixed time of 30
seconds, in order to draw attention. The panic vocal call and SMS are send (if
enabled).
Partialization
Special arming mode of control panel, it exclude a group of zones. In this way
a part of the protected area will not be monitored by the system and it will be
possible to move inside this area without alarm even if the system is armed
BUS device
Device connected to control panel by a 4 wires cable (BUS RS485) (usually
keyboards, key readers and expansion boards)
PreAlarm
Only for PARTIAL armings.
At the start of alarm, the siren sounds at low level – for a programmed time –
and then continue at high level.
During the pre-alarm no SMS or vocal call are sent.
Sensor
Device for violation detection with different technologies (glass breaking,
intrusion, door opening, ecc.)
Sounds
On keyboards some sounds are disabled – with variable time – when the user
or installer make some operation:
simple operations
sounds disabled for about 30 seconds
programming or event queue
sounds disabled for 10 minutes
The disabled sounds are:
entry and exit sounds
pre-alarm
monitor and technologic
maintenance
LCD / OLED
keyboard
Keyboard provided with display LCD / OLED, buttons and LEDs and with which
the user/installer interact with the alarm system. The keyboard allows the
control panel programming.
Entry Time
It is possible to program some zone – when violated – to cause siren sound
only after a certain time.
Useful for example if the control panel is far from entry door and it is
necessary to go near to it to disarm the system.
Exit Time
It is possible to set a time that allow to arm the system and exit from the
building without generate alarm.
Output
There are four outputs on control panel, which are activated according to
some combined event (ex.: to switch on a lamp in case of alarm or to activate
a phone dialler)
BASE mode: the outputs are pre-programmed