![Duevi CE818 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/duevi/ce818/ce818_user-manual_2538414004.webp)
4
GLOSSARY
Alert
Function for generate a “din-don” tone from keyboards and key readers AT
SYSTEM DISARMED when selected zones are violated
Power Fail
If the 230 V
AC
power line fall down for a long time (programmable timing), the
control panel will advice and activate a dedicated output (automatic restore
when power line backs up).
Useful for example to activate a phone call in case of black out
Beep
Word to indicate a treble sound emitted by keyboard or key reader each time
a button is pressed, you interact with the system or to signal an event
Boop
As per “Beep”, this word indicates a bass sound emitted by keyboard or key
reader in particular circumstances
Buzzer
Sound generator inside keyboards and key readers
Electornic Key
Electronic key with digital security code enabled to activate/deactivate the
control panel. Must be used with the key reader
Remote Code
(only if connected the GSM dialler and/or the PSTN module) Four digit security
code for use of GSM/PSTN commands and functions. This code must be
inserted in each command sent to the dialler.
User Code
Six digit code used to access to alarm system using the keyboard
Coercion
This function allow to obtain a silent alarm signalling in case you are forced to
disarm the system under menace.
It is possible to use this function in two modes:
•
after the disarming of the system do NOT press any directional key on
DVT-LCD/OLED keyboard within programmed time
•
press a dedicated button connected by wire to one of the input of the
control panel
PSTN Dialler
Device – optional – to send vocal messages via landline connection. In this
control panel this device is an additional module installed onboard
GSM Dialler
Additional external device (optional) to send vocal and SMS messages using
the GSM network service. The connection with the control panel is realized on
BUS 485 (mod. GSM BUS)
Exclusion/bypass
Function that allow the user to exclude the wanted zones so to bypass them at
system armed
Arming / Disarming
Action of the user to activate/deactivate the alarm system. At system armed
the violation of a zone generates alarm. At system disarmed the violation of
the zones does not generate alarm.
LED
Lights, for different signallings, on keyboards and key readers
Key Reader
These devices read the transponder electronic keys
Содержание CE818
Страница 1: ...1 Made in Italy CE818 User Manual 14 07 M1 5 1 H2 0 F1 41 S1 41 ENG...
Страница 10: ...10 BASE MODE...
Страница 15: ...15 ADVANCED MODE...
Страница 28: ...28...