background image

6

INSTRUCTION FOR THE USER

Cancelling the heat-up function

Touch the (-) (Key 1) sensor while the heat-up 

function is ON to cancel it. The cooking level goes 

down.

When the heat-up function is cancelled, there 

is a sound signal and the decimal point on the 

display goes out. It shows blinking an “H” with 

the cooking level 0, when the temperature of the 

heating-element reaches 65°C. It appears fixed if 

the touch control is switch-off.

Setting the Key Lock function

Keep the Key Lock (Key 10) sensor pressed to 

activate/cancel the keyboard locking function. If the 

LED (11) associated with the Key Lock sensor is 

on, the keyboard is locked.

The locking function can be activated when the 

cooking levels are activated or when the cook top 

is off. If the cook top is on, the Key Lock function 

locks all the sensors except the On/Off (Key 6) 

general sensor and the key lock sensor. When 

the cook top is turned off, the Key Lock function 

blocks all the sensors, including the general On/Off 

switch, except the key lock sensor.

Cancellation of the Key Lock function

If the keyboard is locked (the LED (11) associated 

with the Key Lock (Key 10) sensor is on), keep the 

Key Lock sensor pressed for 1 second to cancel 

the locking function and the indicator light will go 

out.

Residual heat indicators

While the temperature on the cook top glass 

surface is above 65°C, this condition will be shown 

in the associated display, by means of an “H”.

If the cook top is switched off, residual heat is 

shown by a static “H” in the display. If the cook 

top is on, but the power level is 0, the associated 

display will show alternately “H” and “0”.

To generate a temperature above 65°C a heating 

element has to be in operation for a certain time, 

which depends on the selected power level. Once 

this time is passed, the residual heat warning will 

come into operation when the element is switched 

off.

If the minimum time needed to exceed 65°C is 

over, the length of time the residual heat indicator 

remains in operation is a function of the time the 

element has remained turned on at a certain power 

level.

Safety auto-power-off

If the power level is not changed for a present time, 

the element in question will automatically be turned 

off. The maximum operating time of an element 

dependson the cooking level selected.

POWER 

LEVEL

MAXIMUN TIME OF 

FUNCTIONNING (HOURS)

1

10

2

5

3

5

4

4

5

3

6

2

7

2

8

2

9

1

Thermal protection of the control panel

When the control panel detects an ambient 

temperature above 96°C it turns off the nearest 

element (selected by software), and an “H” for 

residual heat shows in the associated display.

An element turned off by the thermal protection 

can only be re-activated when the temperature 

falls below 89°C.

Timer operation

The timer is activated by pressing the (+) or (-) 

(Key8) timer sensors. It can be set to any value 

between 1 and 99 minutes and can modifies at any 

moment. To cancel the timer, select the <00> value 

using the (-) timer sensor or switch it of by pressing 

the (+) and (-) timer sensors simultaneously.

The timer can be customised to suit the needs of 

the user by configuring the following options:

 

Increase of timer value (1 min.).

 

Timed heating element (programmable).

 

Indication of timed heating element.

 

Duration of the acoustic alarm (1 min.).

 

Default initial timer value.

 

Timer-Alarm mode.

Содержание C04-M1

Страница 1: ...oducts We are sure that this new appliance manufactured with quality materials will meet your requirements in the best possible way The use of this new equipment is easy However we invite you to read...

Страница 2: ...of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Unattended...

Страница 3: ...3 GENERAL NOTICE Don t use a steam cleaner for the cleaning the hob...

Страница 4: ...cooking setting 8 Selection of timer setting 2 Cooking setting position 9 Timer position 3 Connection key front left 10 Locking of the cooking surface connection and selection 4 Connection display fr...

Страница 5: ...a double cooking area Each cooking areahas an associated LED Led 4 13 Touch the double area selector to select deselect the double cooking area If one heating element has 1 double area the procedure...

Страница 6: ...wer level is 0 the associated display will show alternately H and 0 To generate a temperature above 65 C a heating element has to be in operation for a certain time which depends on the selected power...

Страница 7: ...t selection we do not indicate a time different than 00 in 10 sec The timer will switch off It could be possible to temporized a heating elementwith power level 0 Indication of timed heating element T...

Страница 8: ...he heating element he or she wishes to time To select a heating element simply press either the or 1 sensors of the chosen heating element Timer mode once the heating element has been selected the Led...

Страница 9: ...appliance is not provided with cable and or relative plug apply a standardized plug to the power supply cable If you wish a direct connection to the line it is necessary to interpose a means for disc...

Страница 10: ...3X2 5 mm 2 H05RR F 4X2 5 mm 2 380 415 V 2N 380 415 V 3N H05RR F 5X2 5 mm 2 H05RR F 3X2 5 mm 2 220 240 V 2 220 240 V 3 H05RR F 4X2 5 mm 2 Cod 205074 02 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 L1 L2 L3...

Страница 11: ...11 135 mm 790 mm 335mm 160 mm 450 mm 600 mm 130 mm 135 CUT OUT DIMENSION...

Страница 12: ...l recycling treatment and environmentally friendly disposal helps reduce possible negative effects on the environment and health and also enables the materials making up the product to be recycled For...

Отзывы: