6
INSTRUCTION FOR THE USER
Cancelling the heat-up function
Touch the (-) (Key 1) sensor while the heat-up
function is ON to cancel it. The cooking level goes
down.
When the heat-up function is cancelled, there
is a sound signal and the decimal point on the
display goes out. It shows blinking an “H” with
the cooking level 0, when the temperature of the
heating-element reaches 65°C. It appears fixed if
the touch control is switch-off.
Setting the Key Lock function
Keep the Key Lock (Key 10) sensor pressed to
activate/cancel the keyboard locking function. If the
LED (11) associated with the Key Lock sensor is
on, the keyboard is locked.
The locking function can be activated when the
cooking levels are activated or when the cook top
is off. If the cook top is on, the Key Lock function
locks all the sensors except the On/Off (Key 6)
general sensor and the key lock sensor. When
the cook top is turned off, the Key Lock function
blocks all the sensors, including the general On/Off
switch, except the key lock sensor.
Cancellation of the Key Lock function
If the keyboard is locked (the LED (11) associated
with the Key Lock (Key 10) sensor is on), keep the
Key Lock sensor pressed for 1 second to cancel
the locking function and the indicator light will go
out.
Residual heat indicators
While the temperature on the cook top glass
surface is above 65°C, this condition will be shown
in the associated display, by means of an “H”.
If the cook top is switched off, residual heat is
shown by a static “H” in the display. If the cook
top is on, but the power level is 0, the associated
display will show alternately “H” and “0”.
To generate a temperature above 65°C a heating
element has to be in operation for a certain time,
which depends on the selected power level. Once
this time is passed, the residual heat warning will
come into operation when the element is switched
off.
If the minimum time needed to exceed 65°C is
over, the length of time the residual heat indicator
remains in operation is a function of the time the
element has remained turned on at a certain power
level.
Safety auto-power-off
If the power level is not changed for a present time,
the element in question will automatically be turned
off. The maximum operating time of an element
dependson the cooking level selected.
POWER
LEVEL
MAXIMUN TIME OF
FUNCTIONNING (HOURS)
1
10
2
5
3
5
4
4
5
3
6
2
7
2
8
2
9
1
Thermal protection of the control panel
When the control panel detects an ambient
temperature above 96°C it turns off the nearest
element (selected by software), and an “H” for
residual heat shows in the associated display.
An element turned off by the thermal protection
can only be re-activated when the temperature
falls below 89°C.
Timer operation
The timer is activated by pressing the (+) or (-)
(Key8) timer sensors. It can be set to any value
between 1 and 99 minutes and can modifies at any
moment. To cancel the timer, select the <00> value
using the (-) timer sensor or switch it of by pressing
the (+) and (-) timer sensors simultaneously.
The timer can be customised to suit the needs of
the user by configuring the following options:
•
Increase of timer value (1 min.).
•
Timed heating element (programmable).
•
Indication of timed heating element.
•
Duration of the acoustic alarm (1 min.).
•
Default initial timer value.
•
Timer-Alarm mode.