background image

 5

 

 

This is very dependent on the judgement and experience of the person given this task and will be subject to a 
certain amount of trial and error.

 

 

After a period of time replacing primary or secondary filters will no longer restore the pressure gauge readings 
to the 

start values

’. 

For example, reading 350 Pascals initially, after a number of primary and secondary filter 

changes may read 650 Pascals, this would be an indication to the user that the HEPA has a significant loading of 
dust and may require replacement.

 

 

When taking pressure gauge readings, the following needs to be borne in mind, the use of flexible ducting will 
affect the performance of the equipment and also increases or decrease pressure gauge readings depending on 
whether the ducting are used on the inlet or outlet of the machine. 

 

 

The ideal method of use is for the appliance to be situated against the outside of the enclosure with the inlet 
spigot (or open front section) passing through polythene and the pre filter box (three stage model) mounted 
internally so that the pre filter can be changed by the persons working inside. Two stage machines have an 
open front section, the pre filter can be changed inside the closure by removing the clamp frame.

 

 

Whenever possible the machine should be situated opposite to the airlock to provide a flow of air across the 
working area.

 

 

For three stage machines the intermediate filter can be changed by removing the front section, this may be 
held on with clips or bolts depending on the model and replacing the filter ensuring the direction of airflow 
shown on the filter is observed.

 

 

For all model

s user changing of the HEPA filter is not recommended as the filter is easily subject to damage and 

unless a DOP test is carried out, filter and filter seal integrity cannot be guaranteed.

 

 

List of Spare parts E

-

vac 5400 

-

 110v & 240v

 

 

F07 

-

 Intermediate Pre

-

filter G4 594mm x 594mm x 95mm

 

 

F25 HEPA filter 

-

 H14 

 