background image

4

L1023004-D

 – 

User manual for Duco's ventilation systems

2B.  Operation with Duco's User controller

The operation of the system is dependent on the type of User controller: 
wired power supply (4 TOUCH buttons / LEDs) or battery power (4 PUSHb 1 LED).

Depending on the software version of the system and its components, some of the functions below may 
not be available.

OPERATION WITH LIGHT-EMITTING BUTTONS

OPERATION WITH LED IN THE CENTRE

Touch button / LED

AUTO

Push button

LED

AUTO

Wired power supply

Battery powered

Содержание System C series

Страница 1: ...e room As standard ventilation operates only until the CO2 standard concentration has dropped below 800 ppm parts per mil lion and remains below that level By way of comparison the CO2 level of the ai...

Страница 2: ...corporated in windows window frames a sliding door or an outside wall Your ventilation system may include manual and or Tronic electronically controlled window ventilators Manual win dow ventilators r...

Страница 3: ...tors will open automatically to 50 High setting The system exhausts at 100 of maximum capacity Ensure that manual window ventilators are open Tronic window ventilators will open automatically to 100 T...

Страница 4: ...er controller wired power supply 4 TOUCH buttons LEDs or battery power 4 PUSHbuttons 1 LED Depending on the software version of the system and its components some of the functions below may not be ava...

Страница 5: ...C system does not have an automatic mode available the AUTO button has the following function Press the button 1 2 or 3 times to put the system in a temporary high setting for 15 30 or 45 minutes res...

Страница 6: ...ettings AUTO approx 5 sec to AUTO AUTO Wired power supply By long pressing or until the 4 LEDs light up briefly the respective setting will be activated permanently for the zone in which the user is l...

Страница 7: ...ower supply Long press until the 4 LEDs light up briefly to activate permanent low setting The low setting will light up magenta After that long press until the 4 LEDs light up briefly to activate uno...

Страница 8: ...e ventilation position on the 3 position switch can therefore be overruled by another User controller such that an incorrect ventilation position will be visible on the 3 position switch The Duco User...

Страница 9: ...sing in progress after system restart Flashing LED s There is a problem with the component network Please contact your installer 3B Switching LED indications on off A controller with a wired power sup...

Страница 10: ...t Onderhoudsinstructies Duco Ventilatiesystemen L8000013 on www duco eu for detailed instructions 4B Battery powered controller The battery in a battery powered controller lasts 3 to 5 years in normal...

Страница 11: ...ill depend on the number of rooms being ventilated Energy consumption will be reduced to a minimum by using pressure controlled fans Do I need to maintain the system Yes please contact your installer...

Отзывы: