User manual for Duco's ventilation systems

1B.  Which system do I have?

The capabilities of your ventilation system will depend on the configuration of the system. Please contact your Duco installer 
if you don’t know which ventilation system you have. A Duco Demand-Controlled Natural Ventilation System consists of the 
following:

•  Central extract unit 

This unit extracts polluted air as required. E.g. a DucoBox.

•  Air duct network (not a Duco product) 

polluted air is extracted to the central extract unit via ventilation ducts to different rooms. 
Note: depending on the configuration of your system, not every room will be ventilated directly. Rooms in which there 
is no exhaust duct provided are ventilated via feed-through to other rooms. This can be done for instance with a window 
ventilator in internal doors or an air gap under them.

•  One or more sensors* 

CO

2

 and/or humidity sensors monitor air quality and detect presence. Sensors can be incorporated in a User controller 

in the room, or built into air ducts.

•  One or more User controllers 

For manual operation of the ventilation system.

•  Window ventilators 

Fresh air is supplied via window ventilators incorporated in windows, window frames, a sliding door or an outside wall. 
Your ventilation system may include manual and/or Tronic (= electronically controlled) window ventilators. Manual win-
dow ventilators require to be opened and shut by the user. Tronic window ventilators are electronically controlled window 
ventilators which open and shut automatically as the system sees fit.

* Exception: Duco C System

You will need to leave manual window ventilators at least partially open in 

order to guarantee automatic system operation.

CENTRAL OR ZONAL EXHAUST?

With central exhaust (= non-local exhaust), ventilation is provided across the entire system. The ventilation system will 
therefore exhaust air from all rooms at all times, regardless of where the polluted air is detected or in which room the user 
has operated the system. The system therefore has just one zone.

With zonal exhaust (= local exhaust), the system only exhausts polluted air in the zone where it is required. Accordingly, a 
User controller will only control the relevant zone, unless the User controller is set to ‘master’ operation (= operating the 
entire system). A zone may consist of one or more rooms (e.g. living room + kitchen).

Note: some settings (see below in this manual) apply only to the room in which the user is located. In central-exhaust sys-
tems, i.e. with just one zone, these settings apply to the whole system.

Содержание System C series

Страница 1: ...e room As standard ventilation operates only until the CO2 standard concentration has dropped below 800 ppm parts per mil lion and remains below that level By way of comparison the CO2 level of the ai...

Страница 2: ...corporated in windows window frames a sliding door or an outside wall Your ventilation system may include manual and or Tronic electronically controlled window ventilators Manual win dow ventilators r...

Страница 3: ...tors will open automatically to 50 High setting The system exhausts at 100 of maximum capacity Ensure that manual window ventilators are open Tronic window ventilators will open automatically to 100 T...

Страница 4: ...er controller wired power supply 4 TOUCH buttons LEDs or battery power 4 PUSHbuttons 1 LED Depending on the software version of the system and its components some of the functions below may not be ava...

Страница 5: ...C system does not have an automatic mode available the AUTO button has the following function Press the button 1 2 or 3 times to put the system in a temporary high setting for 15 30 or 45 minutes res...

Страница 6: ...ettings AUTO approx 5 sec to AUTO AUTO Wired power supply By long pressing or until the 4 LEDs light up briefly the respective setting will be activated permanently for the zone in which the user is l...

Страница 7: ...ower supply Long press until the 4 LEDs light up briefly to activate permanent low setting The low setting will light up magenta After that long press until the 4 LEDs light up briefly to activate uno...

Страница 8: ...e ventilation position on the 3 position switch can therefore be overruled by another User controller such that an incorrect ventilation position will be visible on the 3 position switch The Duco User...

Страница 9: ...sing in progress after system restart Flashing LED s There is a problem with the component network Please contact your installer 3B Switching LED indications on off A controller with a wired power sup...

Страница 10: ...t Onderhoudsinstructies Duco Ventilatiesystemen L8000013 on www duco eu for detailed instructions 4B Battery powered controller The battery in a battery powered controller lasts 3 to 5 years in normal...

Страница 11: ...ill depend on the number of rooms being ventilated Energy consumption will be reduced to a minimum by using pressure controlled fans Do I need to maintain the system Yes please contact your installer...

Отзывы: