13) Electrical and mechanical specifications
Dimensions and weight
: 177 x 247 x 92 mm - 1,2 Kg
Mains power supply
: 230 Vac +/- 10%
Stand-by power consumption
: approx. 1 W
Operating temperature range
: 0 to + 60 °C
Single-phase motors power supply
: 230 Vac 1 HP max
Blinker power supply
: 230 Vac 40 W max
Courtesy light power supply
: 230 Vac 40 W max
Open gate lamp power supply
: 230 Vac 40 W max
Electric lock power supply
: 12 Vac 15 W max
Accessories power supply
: 24 Vac 0.5A max
Motors’ work time
: programmable, 0 to 250 sec.
Pause time
: programmable, 2 to 250 sec.
2
nd
wing closing delay
: programmable, 0 to 25 sec.
Operating frequency
: 433,92 MHz
Caution :
The unit must be not switched on if the connected loads or the power supply exceed the a.m. limits. Failure to observe this precaution can
result in damage to persons, animals or objects for which the manufacturer cannot be held responsible.
14) Electric connections
6 electric connectors are fitted to the card :
1) J2
8-pole Terminal board for the connection of the devices operating with 230 Vac mains power supply (motors and blinker).
2) J5
10-pole Terminal board for the connection of the devices operating at low voltage (commands, safety devices, electric lock and 24 Vac power
supply output)
3) J4
4-pole Terminal board for the connection of the auxiliary devices operating with 230 Vac mains power supply (courtesy light, and open gate
lamp)
4) J1
2-pole Terminal board for the connection of the aerial cable
5) J7
3-pole Terminal board for the connection of the mains power supply and the ground cable
6) J6
10-pole connector for the optional connection of a radio receiver card
Terminal board J2
Terminal 1 -
230 Vac motor M1 power supply phase (opening)
Terminal 2 -
230 Vac motor M1 power supply phase (closure)
Terminal 3 -
230 Vac motor M1 Power supply common
Note
: connect the capacitor of the motor M1 between terminals 2 and 1
Terminal 4 -
230 Vac motor M2 power supply phase (opening)
Terminal 5 -
230 Vac motor M2 power supply phase (closure)