Degrees Fahrenheit or Celsius (C1)
Select ºC or ºF with the
+/-
buttons and confirm with OK button.
Type of Control (C2)
This advanced setting shows the type of control currently used. There are 5 types of control: PID, hysteresis
of 0.25ºC, hysteresis of 0.35ºC, hysteresis of 0.50ºC and hysteresis of 0.75ºC.
To change the type of control press +/-. Confirm with the
OK
button.
The screens shown are:
Temperature Compensation (C3)
In this mode the display will alternate between the temperature compensation (offset) and the measured
temperature with the offset applied. Alter the offset with the
+/-
buttons and confirm with the
OK
button.
Temperature compensation can be adjusted up to +/- 3ºC.
Firmware Version (C4)
It shows internal software installed in the electronics.