background image

MAX VENT LENGTHS FOR COUNTERFLOW

UNIT DIMENSIONS

DUCT SUPPLY 

DUCT RETURN 

AIR INLET &

LENGTH

WIDTH

HEIGHT

OPENING

CUT-OUT

VENT PIPE DIA.

MODEL NUMBER

A

B

C

D

E

F

G

CMPB050C3B

29-1/2

13-1/2

47-3/8

11-1/2

18-15/16

12

21-5/8

2   

CMPB075C3B

29-1/2

13-1/2

47-3/8

11-1/2

18-15/16

12

21-5/8

2

CMPB100C4B

29-1/2

17

47-3/8

15

18-15/16

15-1/2

21-5/8

3

CMPB125C5B

29-1/2

20-1/2

47-3/8

18-1/2

18-15/16

19

21-5/8

* all dimensions in inches

GENERAL LAYOUT

Non-direct Vent (1Pipe) System

60

58

55

53

50

50,000 & 75,000 BTUH

Direct Vent (2 Pipe) System

60

58

55

53

50

50,000 & 75,000 BTUH

APPLICATION

Allowable Max Vent Lengths of 2” Dia. PVC, ABS or CPVC SCH 40 PIPE

Number of elbows

1

2

3

4

5

APPLICATION

Allowable Max Vent Lengths of 3” Dia. PVC, ABS or CPVC SCH 40 PIPE

Number of elbows

1

2

3

4

5

Non-direct Vent (1Pipe) System

80

76

73

70

65

50,000 & 75,000 BTUH

Direct Vent (2 Pipe) System

80

76

73

70

65

50,000 & 75,000 BTUH

Non-direct Vent (1Pipe) System

65

61

58

55

50

100,000 BTUH

Direct Vent (2 Pipe) System

65

61

58

55

50

100,000 BTUH

Non-direct Vent (1Pipe) System

50

46

43

39

35

125,000 BTUH

Direct Vent (2 Pipe) System

50

46

43

39

35

125,000 BTUH

"E" O.D.

1

"C"

15

23 1/4

"A"

"G"

3/4

7 5/16

"B"

"F"

"D" O.D.

AIR INLET

CONNECTIONS *

"H" (AIR INLET DIA.)

SIGHT GLASS

CONDENSATE

DRAIN

(EITHER SIDE)

GAS INLET
(EITHER SIDE)

VENT CONNECTION *
"H" (FLUE DIA.)

THERMOSTAT
CONNECTIONS
(EITHER SIDE)

CONTROL BOX 
ACCESS PANEL

ELECTRICAL

CONNECTIONS

(EITHER SIDE)

BLOWER

ACCESS

PANEL

LOUVERED

ACCESS

DOOR

BURNER

ACCESS

PANEL

DOWNFLOW

VENT 

EXIT

TOP

VIEW

Содержание Fits-All 92

Страница 1: ...aximizes durability VENTING Category IV appliance Can be vented horizontally or vertically using 2 or 3 Schedule 40 PVC ABS or CPVC see installation manual for details Approved for 2 pipe direct vent or single pipe applications Approved for installations with listed concentric vent kit CONTROLS Direct 115V Hot Surface Ignition system with LED diagnostic for fast accurate troubleshooting Slow openi...

Страница 2: ...B CMPB075C3B CMPB100C4B CMPB125C5B BLOWER EXTERNAL STATIC MODEL NUMBER SPEED 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 CMPB050C3B LOW 1080 1060 1030 1000 965 905 840 765 655 525 10 X 6 WHEEL 1 3 HP MOTOR MED 1330 1280 1225 1175 1110 1040 965 875 770 630 HIGH 1490 1420 1360 1285 1205 1125 1070 985 880 750 CMPB075C3B LOW 1080 1060 1030 1000 965 905 840 765 655 525 10 X 6 WHEEL 1 3 HP MOTOR MED 1330 12...

Страница 3: ...IPE Number of elbows 1 2 3 4 5 APPLICATION Allowable Max Vent Lengths of 3 Dia PVC ABS or CPVC SCH 40 PIPE Number of elbows 1 2 3 4 5 Non direct Vent 1Pipe System 80 76 73 70 65 50 000 75 000 BTUH Direct Vent 2 Pipe System 80 76 73 70 65 50 000 75 000 BTUH Non direct Vent 1Pipe System 65 61 58 55 50 100 000 BTUH Direct Vent 2 Pipe System 65 61 58 55 50 100 000 BTUH Non direct Vent 1Pipe System 50 ...

Страница 4: ...20272002 NATURAL TO LP GAS CONVERSION KIT 20269402 HIGH ALTITUDE HIGH ALTITUDE PRESSURE SWITCH KIT 20274505 20274506 FILTER RACK KIT 20069901 20069902 CON 2 DIA VENT TERM KIT 20280901 CON 3 DIA VENT TERM KIT 20280902 20592502 Replaces 20091128 Printed on recycled paper 193400 WP GA 1 01 50K www ducanehvac com For more information contact your local Ducane distributor CMPB050C3B CMPB075C3B CMPA100C...

Отзывы: