5.2 Protection against liquids
5.3 Movement
5.4 Risk of fire
5.5 Forced ventilation
5.6 Ambient temperature
6.1 Protection
The projector contains electric and electronic components which should under no
circumstances come into contact with oil, water or any other liquid. The proper working
of the unit would be compromised should this occur.
The projector has a maximum movement of 540° in the base and 270° in the yoke. DO
NOT place any obstructions in the path of the projector's movement.
Each fixture produces heat and must be installed in a well-ventilated position. The
minimum recommended distance from flammable material is 0.5m. Minimum distance
from the object being illuminated is 2 m.
You will note, on inspection, that the fixture features various air inlets and cooling fans
located on both the base and head of the fixture. These should, under no circumstances,
be blocked or obstructed whilst the projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper
operation.
The projector should never be installed in places that lack a constant flow of air. The
ambient temperature should NOT exceed 35°C.
XR250WASH operates at voltage 230V at 50 or 60Hz.
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is of a suitable rating of 8 amps at 230V.
Strict adherence to regulatory norms is strongly recommended.
The use of a thermal magnetic circuit breaker is recommended for each XR250WASH.
A good earth connection is essential for the correct operation of the projector.
6- MAINS CONNECTION
230V a 50 o 60Hz
5
XR250
W A S H
540°
135°
135°