2- IMPORTANT SAFETY INFORMATION

2.1 Fire prevention:

2.2 Prevention of electric shock:

2.3 Protection against ultraviolet radiation:

2.4 Safety:

2.5 Level of protection against the penetration of solid and liquid matter

1. XR250WASH uses a Philips MSD250/2 lamp . The use of any alternative lamp is not

recommended and will null and void the fixture's warranty.

2. Never locate the fixture on any flammable surface.

3. Minimum distance from flammable materials: 0.5 m.

4. Minimum distance from the closest illuminable surface: 2 m.

5. Replace any blown or damaged fuses only with those of identical value. Refer to the

wiring diagram if there is any doubt.

6. Connect the projector to mains power via a thermal magnetic circuit breaker.

- High voltage is present inside the unit. Isolate the projector from the mains supply

prior to performing any function which involves touching the inside of the unit, including

lamp replacement.

- The level of technology inherent in the XR250WASH requires the assistance of

specialised personnel for all servicing. Refer all work to your authorised DTS service

centre.

- A good earth connection is essential for proper functioning of the projector.

Never connect the unit without proper earth connection.

- The fixture should never be located in a position exposed to rain or in areas of extreme

humidity. A steady supply of circulating air is essential.

1. Never turn the lamp on if any of the lenses, filters or the carbon fibre housing is

damaged. Their respective shielding functions will only operate efficiently if they are in

perfect working order.

2. Never look directly into the lamp when it is on.

- The projector should always be installed with bolts, clamps and other fixtures that are

capable of supporting the weight of the unit.

- Always use a second safety chain of a suitable rating to sustain the weight of the unit

in case of the failure of the main fixing point.

- The external surface of the unit, at various points, may exceed 150°C. Never handle the

unit until at least 10 minutes have elapsed since the lamp was turned off.

- Always replace the lamp if any physical damage is evident.

- Never install the fixture in an enclosed area lacking sufficient air flow. The ambient

temperature should not exceed 35°C.

- A hot lamp may explode, so always wait for at least 10 minutes to elapse after the unit

has been turned off prior to attempting to replace the lamp.

Always wear suitable hand protection when handling the lamp.

- The projector is classified as an ordinary appliance and its level of protection against

the penetration of solid and liquid matter is IP 20. XR250WASH uses MSD250/2 Philips

lamps with GY 9.5 base.

The temperature inside the projector can reach 150° C after just 5 minutes, but it can

2

XR250

W A S H

Содержание XR250 WASH

Страница 1: ...XR250 W a s h Show division Show division XR250 W a s h...

Страница 2: ...cts or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles...

Страница 3: ...AL FUNCTION Pg 17 2 1 Fire prevention 2 2 Prevention of electric shock 2 3 Protection against ultraviolet radiation 2 4 Safety 2 5 Level of protection against the penetration of solid and liquid matte...

Страница 4: ...th 6 dichroic high chromatic yield filters 2 filters for temperature colour conversion 3200 K and 5600 K Rainbow effect Effects wheel with modulation of beam shape 0 180 and Frost effect Mechanical di...

Страница 5: ...on exposed to rain or in areas of extreme humidity A steady supply of circulating air is essential 1 Never turn the lamp on if any of the lenses filters or the carbon fibre housing is damaged Their re...

Страница 6: ...pplied in the lamp s packaging Never touch the glass directly but use the tissue provided in the lamp s packaging The GY 9 5 lampbase is not symmetrical DO NOT USE UNDUE FORCE ON THE GLASS In case of...

Страница 7: ...to hang it The structure should also be sufficiently rigid so as not to move or shake whilst the XR7 moves during its operation Four quarter turn fast locks placed on the base of the units allow for...

Страница 8: ...nlets and cooling fans located on both the base and head of the fixture These should under no circumstances be blocked or obstructed whilst the projector is in operation Doing so could cause the fixtu...

Страница 9: ...e to use a dmx terminal the dmx terminal or even more a canon xrl 5 connected with a resistance to 120 ohm between 2 and 3 the resistance is put in the plug of the dmx of the last device that has been...

Страница 10: ...1 Projector 2 A015 If you want to select the next projector just add 14 Projector 3 A029 A Projector 6 A071 The address that has to be set on each projector generally depends on the number of channels...

Страница 11: ...ction desired 10 DISPLAY FUNCTION MENU ENTER DOWN UP DMX IN DMX OUT DISPLAY COURRENT 230V 50 60 Hz 8 XR250 W A S H Up Down MENU ENTER Up Down Up Down Up Down MENU ENTER Up Down Up Down Up Down MENU EN...

Страница 12: ...NTER Slave Slave mode as run by GAM P Synchronised with master Up Down DMX MODE T o select DMX mode 8 10 14 16 channels TEST MODE Device operation test Pcb 8 motors Pcb PAN TILT AUTOMATIC MODE Automat...

Страница 13: ...aster the projectors need not be of the same model On the master unit it is possible to vary the speed of the GAME P SPEE NB It is possible to run GAME P on the other units even though these do not ha...

Страница 14: ...d through even if not programmed You can set the PAN and TILT engines at high speed on your Xr7 Wash Press menu until you see SPEE Press ENTER and select a speed with UP DOWN there are 4 speeds Confir...

Страница 15: ...el only To operate this menu Connect the projector to the DMX controller DMX SIGNAL MUST BE CORRECTLY RECEIVED Reset the XR250WASH reset from the display projector not from the DMX controller While re...

Страница 16: ...light reflector Even a fine layer of dust can reduce the luminous output substantially Regularly clean all lenses and the reflector using a soft cotton cloth dampened with a specialist lens cleaning s...

Страница 17: ...void the danger of the lamp exploding Periodically check all mechanical parts gears guides belts etc For wear and tear replacing them if necessary Periodically check the lubrication of all components...

Страница 18: ...LLOW DARK GREEN EFFECTS GREY STROBE YELLOW COLOUR WHEEL PINK MAGENTA LIGHT BLUE CYAN GOLD ZOOM 2 BLUE FAN 2 GND BLACK FAN 1 30 VDC RED FROM J10 PAN TILT LIGHT GREEN FROM J8 PAN TILT VIOLET MAGNETIC SE...

Страница 19: ...GREEN ENCODER TILT ORANGE ENCODER PAN RED PAN TILT CARD DISPLAY CARD CONECTOR RELAY CARD XR250 W A S H DATA 1 DATA 2 VIOLET LIGHT GREEN MOTOR TILT BROWN DISPLAY 1 DISPLAY 2 ORANGE J J7 IN LAMP OUT LAM...

Страница 20: ...sb 7 EFFECT 7 EFFECT 8 ZOOM 8 ZOOM 9 PAN lsb 10 TILT lsb DMX CHANNEL Parameter 8 7 2 285 DMX range Value Mid point DMX value Move range degrees Mode Option Function KLWH DQ 9LROHW 0DJHQWD 2UDQJH HOORZ...

Страница 21: ...VSHHG HIW URWDWLRQ VSHHG HIW URWDWLRQ VSHHG HIW URWDWLRQ VSHHG PD DMX CHANNEL Parameter 0 52 0 2 285 DMX range Value Mid point DMX value Move range degrees Mode Option Function 1R IXQFWLRQ 0DFUR DMX C...

Страница 22: ...X CHANNEL Parameter 7 7 PVE DMX CHANNEL Parameter 7 DMX range Value Mid point DMX value Move range degrees Mode Option Function 1R HIIHFW URVW HDP VKDSH DMX CHANNEL Parameter 220 DMX range Value Mid p...

Страница 23: ...CHANNEL Parameter 7 7 PVE DMX CHANNEL Parameter 7 7 OVE DMX CHANNEL Parameter 029 0 17 63 DMX range Value Mid point DMX value Move range degrees Mode Option Function 6WDQGDUG DVW PRYHPHQW 9HFWRU PRGH...

Страница 24: ...G PD ODVK FORVHG VSHHG PLQ ODVK FORVHG VSHHG ODVK FORVHG VSHHG ODVK FORVHG VSHHG PD RORXU 0DFUR LQ EODFN RXW 3DQ H 7LOW LQ EODFN RXW 2SHQ DMX CHANNEL Parameter 2 285 DMX range Value Mid point DMX valu...

Страница 25: ...e degrees Mode Option Function 3URSRUWLRQDO FRORXU DMX CHANNEL Parameter 0 17 DMX range Value Mid point DMX value Move range degrees Mode Option Function 3URSRUWLRQDO FRORXU DMX CHANNEL Parameter 2 DM...

Страница 26: ...URVW HDP 6KDSH DMX CHANNEL Parameter 220 DMX range Value Mid point DMX value Move range degrees Mode Option Function 3URSRUWLRQDO DMX CHANNEL Parameter 5 6 7 DMX range Value Mid point DMX value Move r...

Отзывы: