COM A and COM B 

These  LED  indicators  are  green,  blinking  or  off.    A  green  LED  indicates  a  good 
communication  link.    The  LED  blinks  when  data  is  transmitted.    If  the  LED  is  off,  no 

link has been established for that COM port and troubleshooting is required. 

POWER 

This  LED  indicator  is  green  or  off.    A  green  LED  indicates  input  power  is  within 

specifications and the unit has been powered-up.  If you have input power connected 
to the unit and the POWER LED is not on, this can mean: 

1.

 

You need to press the push-button switch to power-up the unit, 

2.

 

Input power is not within specifications, 

3.

 

Input polarity is not correct. 

Additional troubleshooting can further isolate the problem. 

External Antennas 

Two  antennas  are  provided  with  the  TDAS  WET.    Both  antennas  are  required  for 
802.11n communications. 

Basic Care and Handling 

Your TDAS WET unit is designed to operate reliably in dynamic testing environments.  

Though  resistant  to  many  environmental  conditions,  care  should  be  taken  not  to 
subject  the  unit  to  harsh  chemicals,  submerge  it  in  water,  or  drop  it  onto  any  hard 

surface. 

WARNING: 

Electronic  equipment  dropped  from  desk  height  onto  a  solid 
floor  may  experience  as  much  as  10,000 g.    Under  these 
conditions, damage to the exterior and/or interior of the unit is 
likely. 

When  transporting  the  unit,  treat  it  as  you  might  a  laptop  computer  and  you  should 

have  no  problems.    When  not  in  use  or  if  shipping  is  required,  we  suggest  that  you 
always place the unit in the padded carrying case originally provided with your system. 

The TDAS WET is not user-serviceable and should be returned to the factory for service 

or repair. 

Shock Rating 

All crashworthy TDAS equipment is rated for 100 g, 12 msec duration, in all axes and 
can be mounted directly on a vehicle, sled or other dynamic testing device.  Mounting 

methods and mounting bolt selection should be carefully calculated so as to withstand 
expected  shock  loading.    (Please  see  Appendix  B  for  the  unit’s  mechanical 

specifications.) 

Содержание TDAS WET

Страница 1: ...TDAS WET User s Manual April 2012 Rev 4...

Страница 2: ...Shock Rating 6 Mounting Considerations 7 Temperature Rating 7 Using Your TDAS WET with other TDAS Equipment 7 TDAS PRO racks and TDAS G5 Vehicle Docking Stations 7 TDAS PLUS Distributor 7 TDAS PLUS M...

Страница 3: ...e mail support dtsweb com Your e mail is immediately forwarded to all DTS support engineers worldwide and is typically the fastest way to get a response particularly if you need assistance outside of...

Страница 4: ...Overview of TDAS WET Features Built and tested for 100 g dynamic testing environments Supports IEEE 802 11b g n communication protocols Three external antennas to support high speed performance and e...

Страница 5: ...Switch POWER To power up the unit connect sufficient power to the power input connector and press the push button switch for 5 seconds Power up is immediate after which the unit will log into the netw...

Страница 6: ...erate reliably in dynamic testing environments Though resistant to many environmental conditions care should be taken not to subject the unit to harsh chemicals submerge it in water or drop it onto an...

Страница 7: ...TDAS WET can be at either end of the chain or in the middle Using an RDC cable connect the end marked MASTER to either COM port of the rack or vehicle docking station Connect the end marked SLAVE to...

Страница 8: ...TDAS WET and connect the other end to any available port on the TDAS PLUS Crashworthy Battery To enable communications you will need to connect the TDAS WET to other TDAS equipment with the appropriat...

Страница 9: ...TDAS WET User s Manual April 2012 support dtsweb com 9 Rev 4 When using a laptop power save settings and authentication should be disabled The general procedure is outlined below...

Страница 10: ...s so that the number of walls or ceilings is minimized and that direct line of sight with the WAP is maintained whenever possible 2 Position devices so that the signal will travel straight through a w...

Страница 11: ...changing any network parameters They should not be changed without full knowledge of the impact on the communication environment If you have any questions please contact your network administrator fo...

Страница 12: ...2 VDC input 3 Shield 3 4 Chassis 4 Start recording input optically coupled apply 5 V with respect to pin 16 VDC input is connected to the enclosure 5 Soft common 6 Status output 5 V via 110 ohm refer...

Страница 13: ...emo com Their web site and worldwide sales team are very helpful Should you have difficulty obtaining a specific part number they can suggest connector variations or alternates and explain options tha...

Страница 14: ...tic 5 dBi RP TNC plug 6 high 4 ft cable 10300 01030 Antenna extension cable RP TNC M F 3 m 0 675 inches 17 15 mm 4 85 inches 123 2 mm 3 5 inches 88 9 mm 8 16 inches 207 3 mm 7 5 inches 190 75 mm 8 0 i...

Страница 15: ...ber s of the equipment and parameters you are asking about To reset the unit to default parameters 1 Insert a paper clip into the pin hole on the left side of the unit Press for 15 seconds and release...

Отзывы: