17
12- Art-Net / sACN SIGNAL CONNECTION
The unit operates using the Art-Net / sACN signal
(sACN not yet implemented).
Connection between the mixer and the projector must be carried out using a category
5 network cable and a standard RJ45 connector.
12.1-Direct Ethernet operation
For direct Ethernet operation connect the mixer Art-Net / sACN signal via Ethernet
switch to each unit etherCON RJ45 input connector.
For each unit scroll till NETWORK menu (refer to DISPLAY FUNCTIONS for details):
Select under INPUT menu
“Art-Net” or “sACN” as input control signal.
Select under
IP ADDRESS MODE menu “Default”, “Static” or “DHCP” mode.
Select ETH TO DMX menu to OFF.
Set the IP address and Net Mask.
IP address must be different for each unit
on a network
.
Set the Art-Net or sACN Universe.
DMX address: 1
DMX address: 45
DMX address: 89
IP address: 002.214.192.007
IP address: 002.214.192.008
IP address: 002.214.192.009
Universe: 1
Universe: 1
Universe: 1