8- VOLTAGE AND FREQUENCY
The NICK WASH 600 can operate at 90-260 VOLT 50 or 60 Hz.
9- INSTALLATION
NICK WASH 600 may be either floor or ceiling mounted.
For floor mounting installations, the NICK WASH 600 is supplied with four rubber mounting feet on the
base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to
move or shake whilst the NICK WASH 600 is moving.
Two 1/4 turn Fast Locks connections placed in the base of the units allow to hang the NICK WASH 600
by using the Fast Lock ‘C’ clamps provided in the box.
.
9.1- Safety cable
We recommend the use of a safety chain/cord connected to the NICK WASH 600 and to the suspension
truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the
iron cable or chain can bear the weight of the entire unit.
You may attach the safety chain/cord to the attachment point (A) located on the base of the fixture, as
shown in the picture below.
9.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come
into contact with oil, water or any other liquid. The proper unit functioning would be compromised
should this occur.
ARC 1200
9
!
NICK WASH 600
!
A
SAFETY CHAIN/CORD
ATTACHMENT POINT