MAINS CONNECTION
The projector operates at 230V 50/60 Hz (115V 60Hz on request). Prior to connecting the unit
to your mains supply, ensure that the model in your possession correctly matches the mains
supply available. For connection purposes, ensure that your plug is capable of supporting 10
amps at 230V.
Strict adherence to regulatory norms is strongly recommended.
WARNING
IRIS REPLACEMENT
Warning: Remove mains power before replacing the Iris.
1 Remove the top rear cover by loosing the 2 screws on the back side of the unit panel. (Photo 1
and 2)
2 Press the Iris lock and pull up the iris sub assembly (photo 3 and 4)
PERIODIC CLEANING
Lenses and reflectors
Even a fine layer of dust can reduce the luminous output substantially. Regularly clean all lenses
and the reflector using a soft cotton cloth, dampened with a specialist lens cleaning solution.
Fans and air passages
The fans and air passages must be cleaned approximately every 6 weeks. This periodic cleaning
will depend of course, on the conditions in which the projector is operating. Suitable instruments
for performing this type of maintenance are a brush and a common vacuum cleaner or an air
compressor. If necessary, clean the fans and air passages more frequently.
Connect the Mains cable to the external magnetic ballast of the MOON 1200 by using the special
Powercon male cable connector provided in the box.
Do not remove the connecting cable between magnetic ballast and MOON 1200 when the unit is
ON.
HALF POWER
MOON 1200 magnetic ballast is equipped with a Switch that can reduce the lamp power to 50%
of the standard comsumption (575W) .
ATTENTION
We reccomend to not use “HALF POWER” function for a long time because it may cause lamp
damaging.
ENG
ARC 1200
MOON 1200
9
Iris security lock
PHOTO 1
PHOTO 2
PHOTO 3
PHOTO 4
Содержание MOON 1200